id author title date pages extension mime words sentences flesch summary cache txt cord-334277-g3go3u02 Kovac, Marc EDTA-Anticoagulated Whole Blood for SARS-CoV-2 Antibody Testing by Electrochemiluminescence Immunoassay (ECLIA) and Enzyme-Linked Immunosorbent Assay (ELISA) 2020-08-14 .txt text/plain 4725 237 53 While lateral flow test formats can be utilized with whole blood and low sample volumes, their diagnostic characteristics are inferior to immunoassays based on chemiluminescence immunoassay (CLIA) or enzyme-linked immunosorbent assay (ELISA) technology. We addressed the suitability of EDTA-anticoagulated whole blood as an alternative sample material for antibody testing against SARS-CoV-2 by electro-CLIA (ECLIA; Roche, Rotkreuz, Switzerland) and ELISA (IgG and IgA; Euroimmun, Germany). In receiver-operating characteristic curve analysis, all three assays displayed comparable diagnostic accuracy (area under the curve (AUC)) using corrected whole blood and serum (AUCs: 0.97 for ECLIA and IgG ELISA; 0.84 for IgA ELISA). It can thus be concluded that the anti-SARS-CoV-2 antibody results in whole blood corrected for hematocrit with weakly and moderately positive findings are comparable to those obtained from serum. ./cache/cord-334277-g3go3u02.txt ./txt/cord-334277-g3go3u02.txt