key: cord-328768-2qk884x2 authors: Sabatier, Marina; Bal, Antonin; Destras, Grégory; Regue, Hadrien; Quéromès, Grégory; Cheynet, Valérie; Lina, Bruno; Bardel, Claire; Brengel-Pesce, Karen; Navratil, Vincent; Josset, Laurence title: Comparison of Nucleic Acid Extraction Methods for a Viral Metagenomics Analysis of Respiratory Viruses date: 2020-10-06 journal: Microorganisms DOI: 10.3390/microorganisms8101539 sha: doc_id: 328768 cord_uid: 2qk884x2 Viral metagenomics next-generation sequencing (mNGS) is increasingly being used to characterize the human virome. The impact of viral nucleic extraction on virome profiling has been poorly studied. Here, we aimed to compare the sensitivity and sample and reagent contamination of three extraction methods used for viral mNGS: two automated platforms (eMAG; MagNA Pure 24, MP24) and the manual QIAamp Viral RNA Mini Kit (QIAamp). Clinical respiratory samples (positive for Respiratory Syncytial Virus or Herpes Simplex Virus), one mock sample (including five viruses isolated from respiratory samples), and a no-template control (NTC) were extracted and processed through an mNGS workflow. QIAamp yielded a lower proportion of viral reads for both clinical and mock samples. The sample cross-contamination was higher when using MP24, with up to 36.09% of the viral reads mapping to mock viruses in the NTC (vs. 1.53% and 1.45% for eMAG and QIAamp, respectively). The highest number of viral reads mapping to bacteriophages in the NTC was found with QIAamp, suggesting reagent contamination. Our results highlight the importance of the extraction method choice for accurate virome characterization. The development of metagenomics next-generation sequencing (mNGS) has enabled the exploration of whole viral nucleic acids within a clinical sample (human virome) in order to detect pathogens not targeted by conventional PCR and to identify emerging viruses [1] [2] [3] [4] [5] [6] [7] [8] . Several studies have used various mNGS protocols to explore the human virome in diverse clinical samples, including human stools [9, 10] , blood [11, 12] , cerebrospinal fluid [13, 14] , human tissues [15, 16] , and respiratory tract samples [17] [18] [19] [20] [21] . However, the lack of standardization, the cost and duration of sequencing, and the complexity of bioinformatics analysis critically limit the wide implementation of mNGS approaches in clinical labs [22] . In particular, the extraction of viral nucleic acids is a crucial step in the molecular detection of viruses from clinical samples [23] . While there are many manual and automatic extraction methods available, it is important to choose the most sensitive and reliable one for mNGS. Numerous studies evaluating different extraction platforms in terms of their viral qPCR performance have found that the choice of extraction platform has a major impact on the reliability of the diagnostic results [24] [25] [26] [27] [28] [29] . Furthermore, nucleic acid extraction methods can also impact bacteriome profiles [30] [31] [32] as well as the detection of particular viruses with mNGS [16, 23, 27, 29] . Other potential issues related to extraction methods are sample cross-contamination (contamination from one sample to another) [24, 33, 34] and contamination by sequences present in the environment [32, 34] or in the molecular biology reagents (referred to as the kitome) [35] [36] [37] . In viral mNGS studies, these two aspects constitute a major concern and must be precisely evaluated [38] [39] [40] . The impact of nucleic acid extraction methods on human virome characterization, kitome, and cross-contamination has thus far been poorly studied [41, 42] . The aim of this study was to compare two automated extraction platforms commonly used in diagnostic laboratories, the eMAG (bioMérieux, Marcy-l Étoile, France) and the MagNA Pure 24 (MP24) (Roche, Basel, Switzerland), and one manual QIAamp Viral RNA Mini Kit extraction (Qiagen, Hilden, Germany), which is among one of the most popular methods used in research laboratories. The performance of each extraction kit was evaluated in terms of (1) their ability to detect different DNA and RNA viruses in one mock sample and in clinical samples, (2) their sample cross-contamination rate, and (3) the detection of the kitome. The mock virome included known concentrations of five viruses isolated from respiratory samples ( Table 1) . These viruses were selected as representatives of a wide range of virus characteristics, such as different virion sizes (ranging from 30 to 300 nm), the presence or absence of an envelope, different genome lengths (ranging from 7 to 150 kb), different genome types (dsDNA, ssRNA), and different genome compositions (linear, segmented). All the viruses were provided by the virology laboratory at the university hospital of Lyon (Hospices Civils de Lyon). This mix contained the cell culture supernatant of Adenovirus 31 (AdV), respiratory syncytial virus A (RSV-A), herpes simplex virus 1 (HSV-1), influenza A virus, and rhinovirus. For each virus, clinical samples obtained from hospitalized patients were cultured with the appropriate cell line and media, for which the viral supernatant was then collected (Table 2) . Table 1 . List of the five selected viruses included in the mock virome and the clinical respiratory samples. The mock virome consists of known concentrations of five viruses isolated from respiratory samples, selected as representatives of a wide range of virus characteristics (virion size, the presence or absence of an envelope, genome length, genome type (dsDNA, ssRNA), and genome composition (linear, segmented)). All the viruses were provided by the virology laboratory (Hospices Civils de Lyon). Human clinical respiratory samples were obtained from hospitalized patients. dsDNA: double stranded DNA; ssRNA: single stranded RNA. Using the Ct values obtained by semi-quantitative real-time PCR assays (r-gene, bioMérieux, Marcy l'Étoile, France) a mix with an identical Ct value for each virus was prepared. Individual aliquots of 250 µl were prepared in triplicate for each extraction method to evaluate (9 aliquots). Aliquots were stored at −80 • C ( Figure 1 ). Overview of the study design. A mock virome containing five viruses isolated from respiratory samples representative of a wide range of virus characteristics (adenovirus 31, respiratory syncytial virus A, herpes simplex virus 1, influenza A virus, and rhinovirus) was prepared. Human clinical samples were obtained from hospitalized patients (one bronchoalveolar lavage positive for herpes simplex virus 1 (HSV-1) and one nasopharyngeal aspiration positive for respiratory syncytial virus A (RSV-A). No template controls (NTCs) and transport medium samples were implemented in the process to control for sample and kitome cross-contamination. For the automatic extractors, NTCs were interspersed between the samples of each batch (n=3 per batch), whereas for the manual method only 1 NTC was included per batch (n = 1). To assess the reliability and reproducibility of the experimental results, the extractions and next generation sequencing (NGS) workflow were set up in triplicate (for the mock and respiratory samples), using the same amount of sample input. Finally, libraries were sequenced in the same run with Illumina NextSeq 500 ™ using a 2 x 150 paired-end (PE) high-output flow cell. Two additional patient samples-one positive for a DNA virus and one positive for an RNA virus-that were initially sent to our laboratory for routine viral diagnosis were also selected ( Table 1) . These clinical samples were a bronchoalveolar lavage (BAL) positive for HSV-1 and a nasopharyngeal aspiration (NPA) positive for RSV-A. These samples were stored at +4 • C for initial diagnosis and then diluted in transport medium (MEM medium + 1% L-glutamine + 1% fetal bovine serum + 2% Hepes) in order to obtain a sufficient volume for all the tests (up to 2.3 mL). Then, 250 µL aliquots were prepared in triplicate for each extraction method to evaluate (9 replicate samples in total). The aliquots were stored at −80 • C ( Figure 1 ). The selection of the manual kits and the different platforms was based on their commercial and hospital availabilities. The 3 different methods chosen were the NucliSENS eMAG platform (bioMérieux, Marcy l'Etoile, France), the magNA Pure 24 platform (Roche, Basel, Switzerland), and the QIAamp Viral RNA Mini Kit (Qiagen, Hilden, Germany)-all methods widely used in diagnostic laboratories. Frozen samples were thawed and homogenized by vortexing. Nucleic acids were extracted in parallel from 220 µL of the aliquot in triplicate for each kit, according to the manufacturer's instructions. For the NucliSENS eMAG platform, specific protocol B 2.0.1 was selected. For the MP24 platform, protocol pathogen 1000 was selected. In addition, in order to evaluate the cross-contamination during automated extractions, no-template controls (NTC) were regularly interspersed between samples (i.e., 7 samples per series) ( Figure 2 ). The QIAamp Viral RNA Mini Kit was used following the manufacturer's recommendation with the addition of an inert Linear Acrylamide (LA) carrier (Thermo Fisher Scientific, Waltham, MA, USA) to ensure the maximum recovery of nucleic acids. To assess the reproducibility of the experimental results, the extraction and NGS analysis were set up in triplicate (for mock and respiratory samples) using the same amount of sample input. . Nucleic acids were extracted in triplicate from the same aliquot for each kit according to the manufacturer's instructions. In order to evaluate cross-contamination during the automated extractions, an NTC was regularly interspersed between samples (7 samples per series). To evaluate the kitome contamination, a transport medium sample was added in addition to NTC. Here, each color represents a different extraction method. NTC: No Template Control; HSV: Herpes Simplex Virus; RSV: Respiratory Syncytial Virus; TM: Transport Medium. As previously described, we used an mNGS protocol optimized in our lab [43] . Briefly, after thawing all the samples were supplemented with MS2 bacteriophage (Levivirus genus) from a commercial kit (MS2, IC1 RNA internal control; r-gene, bioMérieux) to check the validity of the process. Only the RNA internal control MS2 was added because it validates all the steps of our protocol (including RT stage during amplification) in contrast to a DNA internal control. A no-template control (NTC) consisting of RNase free water was implemented to evaluate the contamination during the process. An additional negative control consisting of viral transport medium was added. For sample viral enrichment, a 3-step method was applied to 220 µL of vortexed sample spiked with MS2 (low-speed centrifugation, followed by the filtration of the supernatant and then Turbo DNase treatment), as described in detail in Bal et al. [43] . After viral enrichment, the total nucleic acids were extracted using one of the three methods selected for the study described above. After random nucleic acid amplification using modified whole transcriptome amplification (WTA2, Sigma-Aldrich, Darmstadt, Germany), libraries were prepared using the Nextera XT DNA Library kit and sequenced with Illumina NextSeq 500 ™ using a 2 x 150 PE high-output flow cell (Illumina, San Diego, CA, USA). High-quality reads were filtered using trimmomatic PE and were further analysed using Kraken 2, followed by Braken for a taxonomic abundance estimation [44] . A custom kraken 2 database made up of (1) human, bacteria, fungi, archaea, and plasmid genome sequences given by kraken 2 and (2) an in-house viral genome database was used (viromedb, personal communication). The viromedb consists of complete viral genome sequences extracted from genbank and refseq subjected to vecscreen and seqclean softwares to remove the vectors and adaptor sequences and dustmasker to remove the low-complexity sequences. To compare the sensitivity of the three extraction methods, the mean proportion of total viral reads and specific viral abundance were determined. Kitome and sample cross-contamination were assessed by normalizing reads in reads per million (RPM), mapping the reads, and transforming them in log 10 (RPM). For the kitome assessment, a sample was considered to be positive for a particular virus when the log 10 (RPM) of this virus exceeded 1. Analyses were performed at the genus taxonomy level, except for the kitome, for which analyses were performed at the family taxonomy level. All the plots were constructed via ggplot2 and statistical analyses were performed with Rstatix using R (version 3.6.1). For all the statistical tests, the Student's t-test was used. The raw sequence data were deposited at SRA (PRJNA665071). Respiratory samples were collected for regular disease management during hospital stay and no additional samples were taken for this study. In accordance with the French legislation relating to this type a study, written informed consent from participants was not required for the use of de-identified collected clinical samples (bioethics law number 2004-800 of August 6, 2004) . During their hospitalization in the Hospice Civils de Lyon (HCL), patients were made aware that their de-identified data including clinical samples may be used for research purposes, and they could opt out if they objected to the use of their data. Three different extraction methods were evaluated: two automated extraction platforms (eMAG and MP24) and a manual extraction kit (QIAamp) (Figure 1 ). To evaluate the sensitivity of each method, the mean proportion of viral reads out of the total reads generated was first compared (Figure 3) . For the mock sample, both eMAG and MP24 yielded significantly higher proportions of viral reads (79.9% and 84.5%, respectively) in comparison with QIAamp (59.4%; p < 0.05 and p < 0.01, respectively). For the HSV-positive BAL, eMAG yielded a higher proportion of viral reads (2.6%) compared with QIAamp (0.5%, p < 0.01), but did not significantly differ with the MP24 (3.9% viral reads). For the RSV-positive NPA, a similar trend was observed, with an average of 4.3%, 3%, and 1.4% viral reads for eMAG, MP24, and QIAamp, respectively. To determine potential bias in the detection of DNA or RNA viruses, the relative abundance of Levivirus (Internal Quality Control) and targeted viruses in each triplicate were then compared ( Figure 4) . Levivirus was detected in all samples for MP24 and QIAamp, and in 8/9 samples for eMAG. For the targeted viruses, all the viruses were detected with all the extraction methods ( Figure 4) . For the mock sample, a difference in the relative abundance of both the RNA and DNA viruses was noted when comparing the extraction methods. The highest relative abundance of RNA viruses was observed using the QIAamp method (8.2% Enterovirus, 2.2% Alphainfluenzavirus, and 0.6% Orthopneumovirus), which was not significantly different from that of eMAG (5% Enterovirus, 1.4% Alphainfluenzavirus, and 0.4% Orthopneumovirus). The lowest relative abundance was obtained with MP24 (2.5% Enterovirus, 0.4% Alphainfluenzavirus, and 0.2% Orthopneumovirus; p < 0.05 only for Alphainfluenzavirus and Orthopneumovirus compared to the QIAamp method). For DNA viruses, the highest relative abundance was obtained using eMAG and MP24 (54.4% and 69.3% for Simplexvirus, respectively, vs. 23.4% with QIAamp; 9.5% and 17.1% for Adenovirus, respectively, vs. 1.3% with QIAamp; p < 0.01). Surprisingly, many reads associated with Dependoparvovirus, an ssDNA virus, were observed in the mock sample after the QIAamp extraction (29.4% with eMAG, 9.9% with MP24, and 61.4% with the QIAamp extraction). The impact of the different extraction methods on sample cross-contamination was then evaluated from the NTC samples included between each sample during the extractions (Figure 2 ) by mapping the read count of viruses that were present in samples from the same batch: internal quality control (MS2, Levivirus) and targeted viruses (Adenovirus, Orthopneumovirus, Simplexvirus, Alphainfluenzavirus, Enterovirus, and Dependoparvovirus) ( Figure 5 ). Levivirus was not found in any NTC extracted by eMAG and QIAamp but was found in 1/9 NTCs extracted by MP24 (MS2 log 10 RPM = 2.1). For the two automatic extractors, the main contaminant was Simplexvirus (HSV1), found in 4/9 NTCs (up to 1.5 log 10 (RPM)) and in 5/9 NTCs (up to 3.7 log 10 (RPM)) extracted with eMAG and MP24, respectively. For eMAG, there was also a high level of Dependoparvovirus contamination in 1/9 NTCs (log 10 (RPM) = 1.2) and of Orthopneumovirus in 1/9 NTCs (log 10 (RPM) = 2.1). For MP24, cross-contamination was noted in the NTC, with all viruses contained in the mock 4/9 NTCs with Mastadenovirus (up to 2.9 log 10 (RPM)), 5/9 NTCs with Dependoparvovirus (up to 2.8 log 10 (RPM)), 3/9 NTCs with Enterovirus (up to 2.1 log 10 (RPM)), 3/9 NTCs with Alphainfluenzavirus (up to 2.1 log 10 (RPM)), and 3/9 NTCs with Orthopneumovirus (up to 1.3 log 10 (RPM)). For the QIAamp manual extractor, the main contaminant was Alphainfluenzavirus (3/3 NTC, up to 2.2 log 10 (RPM)). There were also contaminations with Mastadenovirus (2/3 NTC, up to 1.5 log 10 (RPM)) and with Enterovirus (2/3 NTC, up to 1.8 log 10 (RPM)). Overall, the viral sample cross-contamination represented on average 0.002%, 0.107%, and 0.015% of the total reads generated from the NTC for the eMAG, MP24, and QIAamp extraction methods, respectively (corresponding to 1.53%, 36.09%, and 1.45% of the viral reads for the eMAG, MP24, and QIAamp extraction methods, respectively). Importantly, for MP24 we also noted that sample cross-contamination was more associated with a batch effect than with the position of the sample in the extraction cartridge. Hence, while NTC#1, #2, and #3 were all contaminated, there was less contamination in all NTCs from batch #2 than in the NTCs from the two other batches of extractions ( Figure 5 ). The impact of the different extraction methods on the viral kitome contamination was then evaluated by detecting in the NTC and TM the presence of reads associated with viruses other than the targeted viruses. The log 10 (RPM) of the kitome was significantly higher with the QIAamp extraction compared to the eMAG and MP24 extractions (p < 0.01). The viral kitome contamination generated from the NTC represented an average of 11.31 log 10 (RPM), 16.88 log 10 (RPM), and 70.77 log 10 (RPM) with the eMAG, MP24, and QIAamp extraction methods, respectively (Figure 6a ). showed the viral family read count associated with the kitome (the presence of reads associated with other viruses than the targeted viruses) normalized in log 10 (RPM) in each NTC and TM between the different extraction methods. A gradient of colors was defined from gray (no count) to blue (few counts) to red (highest counts). During the automated extractions, the NTCs were interspersed between samples (i.e., 3 NTCs per batch). For manual extraction, only one NTC was added. In addition to the NTC, transport medium was added. Analyses were performed on the family taxonomical level. A sample was considered to be positive for a particular virus when the log 10 (RPM) of this virus exceeded 1. HSV: herpes simplex virus; RSV: respiratory syncytial virus; NTC: no template control; TM: transport medium; RPM: reads per million. The contaminants derived mainly from bacteriophage families. In particular, Siphoviridae was found in all three methods (ranging from 2.32 to 3.39 log 10 (RPM)), corresponding to 21.4%, 13.7%, and 4.8% of the total viral kitome reported with the eMAG, MP24, and QIAamp extraction methods, respectively. Regarding the transport medium, the viral kitome contamination represented an average of 24.11 log 10 (RPM), 19.94 log 10 (RPM), and 72.45 log 10 (RPM) with the eMAG, MP24, and QIAamp extraction methods, respectively (Figure 6b) . The same main viral families associated with kitome were found for the two automatic extractors with a majority of Poxviridae, while for the manual extractor the main family found was Siphoviridae (Figure 7b) . Overall, the kitome contamination was higher with the QIAamp extraction (p < 0.01). Siphoviridae bacteriophages were found in the three methods, while other contaminants such as Poxviridae were specifically found in the transport medium extracted by the automated methods. In this study, we compared the performance of three extraction methods commonly used in clinical laboratories for viral mNGS analysis (eMAG, MagNA Pure 24, and QIAamp Viral RNA Mini Kit). The extractors yielding the highest proportion of viral reads were the two automatic extractors, eMAG and MP24. A previous study found that Qiagen kits tend to extract a high proportion of human nucleic acids, which could explain the lower viral proportion reported in the present study [29] . Despite this difference, all the viruses present in the mock or clinical samples could be detected with all the methods evaluated herein. Nonetheless, a difference in the relative abundance of RNA and DNA viruses was noted in the mock sample. The highest relative abundance of RNA viruses was reported with QIAamp, and the highest relative abundance of DNA viruses was reported with the eMAG and MP24 platforms. This bias should be taken into account during the interpretation of mNGS studies and underlines the importance of the extraction method choice, depending on the virus to be explored. These differences could be due to the various properties of viruses, including the presence of an envelope, the type of genome, or the size of the virions. Yang et al. showed a better performance of RNA virus recovery with EasyMag (identical silica extraction technology and similar performance to that of Emag [45] ) compared to the MagNA Pure Compact. They explained this difference by a possible RNA degradation or by an ineffective binding of RNA to the magnetic beads [30] . Finally, the higher sensitivity of the QIAamp kit for the detection of RNA viruses might be explained by the kit having been initially intended for the extraction of RNA viruses. The detection of DNA viruses would still be possible through the capture of the RNA transcripts of DNA viruses. Meanwhile, a higher number of reads on RNA viruses for the QIAMP method was noted from the mock sample including both RNA and DNA viruses at equi-Ct; the supplementation of both DNA and RNA internal controls in NTCs would have been interesting for evaluating also the extraction bias in low-biomass samples. In addition to the differences related to the extraction methods, certain types of viruses or genomes can be preferentially amplified as described for the Poliovirus by Lewandoska et al. [23] . Moreover, bioinformatics analysis of mNGS data can also impact the viral reads annotation. The presence of gaps at the level of taxonomic classification (genus) can bias the interpretation for these given taxonomic groups (notably phages). The choice of the viral reference database is therefore crucial in order to limit viral misclassifications or the lack of detection of new emerging viruses [46] . Moreover, short reads reduce the accuracy of viral read assignation. As there is currently no gold standard in de novo assembly software for virome assessment, extensive benchmarking will be necessary in order to choose the most adapted method for future studies. With the new advances in third-generation sequencing and the improvement in sequence quality generated by this approach, we expect that the use of longer reads will led to an increase in specificity as compared to short-read technology. Interestingly, we observed many reads associated with Dependoparvovirus only in the mock sample, especially with the QIAamp extraction. This can be explained by the presence of ADV in the mock, which might be associated with Adeno-associated dependoparvovirus [47] or with contaminants from the QIAamp column [35, 48] . Our internal control (MS2, Levivirus) was detected for all replicates extracted with the three methods, except for two extracts with eMAG. As previously described, competition between the target viruses and MS2 might be observed during the process, leading to undetected MS2 [43] . To date, few studies have assessed the impact of different extraction methods on the performance of metagenomics. Klenner and Paramyxovirus), and reported that the selection of the kits has only a minor impact on the yield of viral reads and the quantity of reads obtained by NGS [28] . However, this study only evaluated manual kits from the same manufacturer and with separate RNA and DNA extraction methods. Conversely, several studies have highlighted the importance of the nucleic acid extraction protocol in producing high-quality extracts suitable for sequencing [23, 27, 29] . Lewandoska et al. compared the impact of three extraction methods (QIAamp Viral RNA mini Kit, PureLink Viral RNA/DNA Mini Kit, and automated NucliSENS EasyMAG) on the recovery of different viral genomes (adenovirus, poliovirus, HHV-4, influenza A virus). The EasyMAG extraction was more efficient for both RNA and DNA viruses, leading to a higher recovery of viral genomes. The mNGS results are highly susceptible to inaccurate conclusions resulting from the sequencing of contaminants [36] . In the present study, the viral contamination was higher with MP24 than with eMAG and QIAamp. Automated extraction platforms may lead to sample cross-contamination due to the generation of aerosols or robotic errors. Knepp et al. compared two automated extractors (BioRobot M48 instrument (Qiagen, Inc.) and MagNA Pure) and did not show contamination with the automated instruments [24] . However, they only investigated cross-contamination related to enterovirus (RNA virus), unlike our study, which evaluated a panel of RNA and DNA viruses. The second source of contamination may come from the reagents (kitome) used throughout the process or from laboratory contaminants. The extractor for which the kitome abundance was highest was the QIAamp. The main contaminants were Siphoviridae, Myoviridae, Microviridae, and Podoviridae, which is consistent with other studies that have reported similar findings with spin columns [34] . In order to monitor the kitome and avoid misinterpretation, it is important to implement negative controls at different steps of the process [38, 42, 49] . Here, we did not add any internal controls in the NTC in order to get the highest sensitivity in detecting the kitome (without using reads to sequence MS2). On the other hand, the internal control MS2 was added in the TMs and was detected in all except one batch of the eMAG extraction in order to estimate the potential contaminants present in the transport medium, as it was previously published that fetal bovine serum contains DNA [50, 51] . Furthermore, a computational approach for removing contaminants of viral origin should be developed, as previously described for bacteriome data [34, 52] . Although the results show higher sample cross-contamination with the MP24 and higher kitome-related contamination with the QIAamp, other steps throughout sample processing can produce contamination. Here, we did not include an NTC at each step of the process to control for other sources of contamination. In addition, only a few respiratory samples were tested herein, and so further studies on a larger number of respiratory samples, as well as on other types of samples (stool, blood, and tissue) or other respiratory viruses (such as the SARS-CoV-2, which has the largest human RNA virus genome), should be performed. While three commonly used extraction methods have been evaluated in this study, it could be interesting to test others. Our findings highlight the importance of extraction method choice for viral mNGS analysis. The eMAG platform yielded a higher proportion of viral reads, with a limited impact of reagents and sample cross-contamination compared to the QIAamp and MP24 extractors. Funding: eMAG ® . The eMAG consumables and R-gene ® kits necessary for this evaluation were provided by bioMerieux France. However, the data obtained during the evaluation were independently analyzed in the virology department of Lyon University Hospital, which possesses the entire final data bank. BioMerieux had no role in the study design, data collection and interpretation, or the decision to submit the work for publication. Unbiased Detection of Respiratory Viruses by Use of RNA Sequencing-Based Metagenomics: A Systematic Comparison to a Commercial PCR Panel Characterization of the nasopharyngeal viral microbiome from children with community-acquired pneumonia but negative for Luminex xTAG respiratory viral panel assay detection Targeted Sequencing of Respiratory Viruses in Clinical Specimens for Pathogen Identification and Genome-Wide Analysis Precision Surveillance for Viral Respiratory Pathogens: Virome Capture Sequencing for the Detection and Genomic Characterization of Severe Acute Respiratory Infection in Uganda Enrichment post-library preparation enhances the sensitivity of high-throughput sequencing-based detection and characterization of viruses from complex samples Two Years of Viral Metagenomics in a Tertiary Diagnostics Unit: Evaluation of the First 105 Cases Viral metagenomics revealed novel betatorquevirus species in pediatric inpatients with encephalitis/meningoencephalitis from Ghana RNA based mNGS approach identifies a novel human coronavirus from two individual pneumonia cases in 2019 Wuhan outbreak Metagenomic Analysis of Viruses in Feces from Unsolved Outbreaks of Gastroenteritis in Humans A Protocol for Extraction of Infective Viromes Suitable for Metagenomics Sequencing from Low Volume Fecal Samples Identification of Hepatotropic Viruses from Plasma Using Deep Sequencing: A Next Generation Diagnostic Tool Metagenomics and the Human Virome in Asymptomatic Individuals Laboratory validation of a clinical metagenomic sequencing assay for pathogen detection in cerebrospinal fluid Clinical Metagenomic Sequencing for Diagnosis of Meningitis and Encephalitis Metagenomic sequencing of "HPV-negative" condylomas detects novel putative HPV types Protocol for Metagenomic Virus Detection in Clinical Specimens Characterization of the Viral Microbiome in Patients with Severe Lower Respiratory Tract Infections, Using Metagenomic Sequencing Evaluation of Unbiased Next-Generation Sequencing of RNA (RNA-seq) as a Diagnostic Method in Influenza Virus-Positive Respiratory Samples Metagenomic analysis using next-generation sequencing of pathogens in bronchoalveolar lavage fluid from pediatric patients with respiratory failure Altered respiratory virome and serum cytokine profile associated with recurrent respiratory tract infections in children Evaluation of a stepwise approach using microbiota analysis, species-specific qPCRs and culture for the diagnosis of lower respiratory tract infections Understanding the Promises and Hurdles of Metagenomic Next-Generation Sequencing as a Diagnostic Tool for Infectious Diseases Optimization and validation of sample preparation for metagenomic sequencing of viruses in clinical samples Comparison of Automated and Manual Nucleic Acid Extraction Methods for Detection of Enterovirus RNA Comparison of QIAGEN Automated Nucleic Acid Extraction Methods for CMV Quantitative PCR Testing Extraction of viral nucleic acids: Comparison of five automated nucleic acid extraction platforms The Effect of Nucleic Acid Extraction Platforms and Sample Storage on the Integrity of Viral RNA for Use in Whole Genome Sequencing Metagenomic analysis of viral nucleic acid extraction methods in respiratory clinical samples Unbiased Parallel Detection of Viral Pathogens in Clinical Samples by Use of a Metagenomic Approach Combined bacterial and fungal targeted amplicon sequencing of respiratory samples: Does the DNA extraction method matter? Impact of DNA Extraction Method on Variation in Human and Built Environment Microbial Community and Functional Profiles Assessed by Shotgun Metagenomics Sequencing Impact of Contaminating DNA in Whole-Genome Amplification Kits Used for Metagenomic Shotgun Sequencing for Infection Diagnosis Laboratory contamination in airway microbiome studies The Perils of Pathogen Discovery: Origin of a Novel Parvovirus-Like Hybrid Genome Traced to Nucleic Acid Extraction Spin Columns Traces of ATCV-1 associated with laboratory component contamination Identification and removal of contaminating microbial DNA from PCR reagents: Impact on low-biomass microbiome analyses Metagenomic Investigation of Plasma in Individuals with ME/CFS Highlights the Importance of Technical Controls to Elucidate Contamination and Batch Effects Assuring the Quality of Next-Generation Sequencing in Clinical Microbiology and Public Health Laboratories Viral Pathogen Detection by Metagenomics and Pan-Viral Group Polymerase Chain Reaction in Children With Pneumonia Lacking Identifiable Etiology Comparing viral metagenomics methods using a highly multiplexed human viral pathogens reagent Contaminating viral sequences in high-throughput sequencing viromics: A linkage study of 700 sequencing libraries Quality control implementation for universal characterization of DNA and RNA viruses in clinical respiratory samples using single metagenomic next-generation sequencing workflow Trimmomatic: A flexible trimmer for Illumina sequence data Beby-Defaux, A. Comparison of eMAG TM versus NucliSENS ® EasyMAG ® performance on clinical specimens Novel NGS Pipeline for Virus Discovery from a Wide Spectrum of Hosts and Sample Types Nucleic acid from an adeno-associated virus: Chemical and physical studies Modular approach to customise sample preparation procedures for viral metagenomics: A reproducible protocol for virome analysis Reagent contamination in viromics: All that glitters is not gold Unbiased analysis by high throughput sequencing of the viral diversity in fetal bovine serum and trypsin used in cell culture Virome of US bovine calf serum Simple statistical identification and removal of contaminant sequences in marker-gene and metagenomics data This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license Acknowledgments: This work was supported by the LABEX ECOFECT (ANR-11-LABX-0048) of Université de Lyon, within the program "Investissements d'Avenir" (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR). We are grateful to Florence Morfin, who provided culture strains of the different viruses in the study. The bioinformatics analysis was performed using the computing facilities of the CC LBBE/PRABI-AMSB. Valérie Cheynet and Karen Brengel-Pesce are employees of Biomérieux. Antonin Bal has received a research grant from bioMérieux and has served as a consultant for bioMérieux. The other authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analysis, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.