key: cord-328373-cubp1cc1 authors: Jiang, Yanfang; Wang, Haifeng; Hao, Sijia; Chen, Yukun; He, Jiaxue; Liu, Yong; Chen, Liguo; Yu, Yuanhua; Hua, Shucheng title: Digital PCR is a sensitive new technique for SARS-CoV-2 detection in clinical applications date: 2020-11-04 journal: Clin Chim Acta DOI: 10.1016/j.cca.2020.10.032 sha: doc_id: 328373 cord_uid: cubp1cc1 The global coronavirus disease 2019 (COVID-19) pandemic has posed great challenges in people’s daily lives. Highly sensitive laboratory techniques played a critical role in clinical COVID-19 diagnosis and management. In this study the feasibility of using a new digital PCR-based detection assay for clinical COVID-19 diagnosis was investigated by comparing its performance with that of RT-PCR. Clinical patient samples and samples obtained from potentially contaminated environments were analyzed. The study included 10 patients with confirmed COVID-19 diagnoses, 32 validated samples of various types derived from different clinical timepoints and sites, and 148 environmentally derived samples. SARS-CoV-2 nucleic acids were more readily detected in respiratory tract samples (35.0%). In analyses of environmentally derived samples, the positivity rate of air samples was higher than that of surface samples, probably due to differences in virus concentrations. Digital PCR detected SARS–CoV–2 in several samples that had previously been deemed negative, including 3 patient-derived samples and 5 environmentally derived samples. In this study digital PCR exhibited higher sensitivity than conventional RT-PCR, suggesting that it may be a useful new method for clinical SARS-CoV-2 detection. Improvement of SARS-CoV-2 detection would substantially reduce the rates of false-negative COVID-19 test results, in particular those pertaining to asymptomatic carriers. Coronavirus disease 2019 (COVID- 19) is an infectious disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). By 20 April 2020 there had been more than 2,360,000 confirmed COVID-19 cases worldwide, and over 165,000 deaths. It has been suggested that the total number of reported SARS-CoV-2 infections is an underestimate of the actual number of infections, due to mild and asymptomatic cases [1] . COVID-19 patients exhibit various clinical courses, but the most common symptoms are fever (43.8% on admission and 88.7% during hospitalization) and coughing (67.8%) [2] . Laboratory tests and computed tomography (CT) scans have been used in clinical practice to diagnose COVID-19 and monitor treatment responses [3] , and more recently multiple SARS-CoV-2 nucleic acid detection kits have been developed. To date real-time reverse-transcriptase (RT) PCR is the most reliable technology for the detection and quantification of target nucleic acid fragments. It constitutes a rapid and accurate method of viral nucleic acid detection, and it has been widely utilized for viral DNA detection in both clinical and environmentally derived samples. The most substantial aspect of real-time RT-PCR is that it facilitates monitoring of the amplification of the target DNA sequence that is reverse-transcribed from RNA, then mathematical quantification of the starting material after background correction [4] . For assays designed for diagnostic applications, viral nucleic acid in a patient-derived sample is often the detection target. Notably however, it has been reported that in clinical practice the false-negative rate of real-time RT-PCR-based assays can be as high as 20% [5] . This potential false-negative rate raises a general concern given its diagnostic purpose, and may result in substantial clinical consequences [5] . There is a need for improvement of detection assays used for COVID-19 laboratory diagnosis. 4 Digital PCR is an emerging technology designed to achieve absolute quantification after real-time PCR, and it has been successfully applied in various fields, including clinical laboratory diagnosis [6] [7] [8] [9] . In the current study the use of a novel digital PCR assay to detect SARS-CoV-2 in both clinical patient-derived samples and environmentally derived samples was investigated, with the ultimate aim of reducing the rate of false negative results. All SARS-CoV-2 tests were performed at a genetic diagnosis center from January 2020 to April 2020. Guidelines were included in the study [10] . The clinical characteristics of the 10 patients are shown in Table S1 . The WHO Interim Guidelines [10] stipulate that a relevant epidemiological history and any two of the following clinical manifestations and pathogenic evidence are indicative of potential COVID-19: Epidemiological history: (1) Within 14 days before the onset of symptoms the patient has engaged in tourism or residence in Wuhan or its surrounding areas, or other communities with confirmed cases; (2) Within 14 days before the onset of symptoms the patient has been in contact with confirmed cases of COVID-19; (3) Within 14 days before the onset of symptoms the patient has been in contact with suspected cases (patients with fever or respiratory symptoms) from Wuhan or its surrounding areas, or other communities with confirmed cases; (4) With regard to aggregation, within 14 days before the onset of symptoms one confirmed case was detected in an enclosed environment (such as a domestic premises, a construction site, or an office) and one or more cases of fever or respiratory tract infection were detected at the same time. Digital PCR improved SARS-CoV-2 detection 5 Clinical manifestations: (1) Fever and/or respiratory symptoms; (2) Imaging indicates multiple mottling and interstitial changes in lung consolidation; (3) In the early stage of the disease the total number of leukocytes was normal or decreased, or the lymphocyte count was decreased. Pathogenic evidence: Nucleic acid test (real-time RT PCR) was used to detect SARS-CoV-2 in the respiratory tract. In the present study SARS-CoV-2 nucleic acid was detected in nasopharyngeal swabs from all patients except patient 9. In patient 9 SARS-CoV-2 nucleic acid was detected in an oropharyngeal swab sample. Thirty-two patient samples including nasopharyngeal swabs, throat swabs, oropharyngeal swabs, phlegm, plasma/blood, and eye conjunctiva were collected at multiple timepoints during the disease course, and tested for the presence of SARS-CoV-2 via RT-PCR. RT-PCR cycle threshold values were determined. Plasma/blood was taken from the cubital vein. A total of 148 environmentally derived samples were collected from potentially contaminated areas. Two isolation ward areas were included in the study, and each area included a nursing station. The environmental samples included air samples and surface samples, and the sample collection points utilized have been described previously [5, 11] . Environmental monitoring was conducted in accordance with the hospital sanitation standards [12] . All air samples were collected by natural sedimentation and a microbial air sampler (MAS-100 ECO) with the air stream set to 500 L (Merck, Germany). Environmental surfaces were sampled via swabs. RT-PCR cycle threshold values were determined. Sample collection and environmental sampling details are shown in Table S2 . Two highly conserved sequence regions were selected for primer and probe design, ORF1ab and N. Digital PCR improved SARS-CoV-2 detection 6 ORF1ab gene The respective expected amplicon sizes of the ORF1ab and N gene assays were 132 bp and 110 bp. All primers and probes were purchased from Integrated DNA Technologies. It was retrospectively confirmed that the primer and probe sequences were perfectly matched with SARS-CoV-2 genome sequences from the Global Initiative on Sharing All Influenza Data (https://www.gisaid.org/; accession numbers EPI_ISL_402119, EPI_ISL_402120, EPI_ISL_402121, EPI_ISL_402123, and EPI_ISL_402124; accessed 12 January 2020). Digital PCR improved SARS-CoV-2 detection 7 All samples were inactivated in 600 µL guanidine hydrochloride buffer, centrifuged at 12000 g for 10 min, then incubated for 30 min. After discarding the supernatant, 50 µL of RNA release agent (Shengxiang, Hunan, China) was added. The samples were then mixed and incubated for 10 min, and the extracted RNA was used for RT-PCR and digital PCR. Rightongene Biotechnology Co., Ltd.). Ten microliters of nucleic acid was added to the preamplification mixture, which contained 25 μL of each reaction system. Pre-amplification was performed at 55°C for 15 min, followed by 95°C for 30 s, then 8 cycles of 95°C for 10 s and 60°C for Droplet preparation was conducted using a droplet generator (Droplet Digital PCR System) and a droplet generator chip. The droplet was then transferred to an RNAse-free PCR tube for PCR amplification. The amplification mixture was prepared using 4 μL ddPCR-A or ddPCR-B and 10 μL ddPCR MIX3 (SARS-CoV-2 Nucleic acid Detection Kit, Shanghai Rightongene Biotechnology Co., Ltd). Amplification was initiated at 95°C for 10 min, followed by 40 cycles of 94°C for 15 s and 58°C for 60 s, then final extension at 98°C for 10 min. After amplification a biochip reader (Droplet Digital PCR System) was used to analyze fluorescence, and a two-color optical detection system was used for image scanning and analysis of each droplet in the sample. Droplets with fluorescent signals were considered positive, and droplets without fluorescent signals were considered negative. Numbers of positive and negative droplets and proportions of positive droplets were calculated. Lastly, based on the Poisson distribution principle and the proportion of positive droplets, analysis software was used to calculate the concentration or copy number of target molecules. Details of the 10 patients diagnosed with COVID-19 included in the current study are shown in Table 1 . The mean age of the initial patient cohort was 56.9 years (range 25-79 years) and 36.4% were male. The patients were clinically classified as mild, moderate, severe, or critical based on C reactive protein. In total 72.7% of patients (n = 10) had more than one listed symptom. The most common clinical symptoms were coughing (54.6%), diarrhea (36.4%), and fever (27.3%). Bilateral pneumonia was evident in CT scans of 81.8% of patients, and unilateral pneumonia was evident in CT scans of 9.1% of patients. Contact tracing indicated that 81.8% of the patients had been in contact with either confirmed COVID-19 cases or people associated with Wuhan. SARS-CoV-2 nucleic acid sequences were detected in all clinical patient samples (respiratory tract samples including nasopharyngeal and oropharyngeal swabs). To investigate associations between positivity rate and sample type, additional testing of 32 samples collected from respiratory and non-respiratory sites in 4 confirmed COVID-19 patients at different timepoints during hospitalization was conducted, and the results are shown in Table 2 . Different positivity rates were associated with different sample types (Table 3) . SARS-CoV-2 was more frequently detected in respiratory tractderived samples (35.0%) than in non-respiratory tract-derived samples (0.0%). The positivity rate was highest in phlegm samples (66.7%), and the detection rate in oropharyngeal swabs (42.9%) was higher than that in nasopharyngeal swabs (28.6%). Of a total of 148 environmentally derived samples collected from potentially contaminated areas, 2 (1.4%) tested positive for SARS-CoV-2 in real-time RT-PCR assays. Compared to samples collected from potentially contaminated surfaces, a higher positivity rate was evident in air samples (1/28, 3.6%). The results suggest that SARS-CoV-2 detection rate may be affected by the pathogen concentration in the environment (Table 4 ). A novel digital PCR-based assay was developed to improve the accuracy of laboratory COVID-19 diagnosis, and all samples previously analyzed via real-time RT-PCR were re-analyzed using that digital PCR-based assay. All samples that tested positive in real-time RT-PCR assays also tested positive in digital PCR assays. Eight additional samples, including 3 clinical patient-derived samples and 5 samples from potentially contaminated environments only tested positive in digital PCR assays (Table 5) . These 3 patient samples were derived from an oropharyngeal swab (from patient 7), blood/plasma (patient 8), and a nasopharyngeal swab (patient 9). The results suggest higher sensitivity of the digital PCR-based assay for SARS-CoV-2 detection in clinical applications. The application of digital PCR for SARS-CoV-2 detection may play a critical role in diminishing the false-negative rate of diagnostic COVID-19 laboratory tests. Numerous clinical symptoms have been reported in COVID-19 patients, and the clinical course can vary from asymptomatic to critical [2] . The most common symptoms of COVID-19 are reportedly fever, coughing, and a sore throat [2, 11] . COVID-19 patients can also present with sputum production, headache, hemoptysis, dyspnea, diarrhea, and lymphopenia [13] [14] [15] . In clinical laboratory tests elevated C-reactive protein and D-dimer as well as decreased levels of lymphocytes, leukocytes, and blood platelets are detected in some COVID-19 patients [2] . Notably however, many COVID patients do not exhibit fever [2, 13, [16] [17] [18] . In the current study 27.3% of patients presented with fever, 54.6% with coughing, and 36.4% with diarrhea. At least one symptom listed was evident in 72.7% of the patients. CT scans depicted clinical features of bilateral pneumonia in 81.9% of patients and unilateral pneumonia in 9.1% of patients. As in some previously reported studies [11] , SARS-CoV-2 nucleic acid sequences were more frequently detected in respiratory tract-derived samples (35.0%) than in non-respiratory tract-derived samples (0.0%). The mucosa of the conjunctiva and upper respiratory tract are connected by the nasolacrimal duct, share the same SARS-CoV-2 entry receptor on cell membranes (angiotensin-converting enzyme 2), and may act as a transmission route for SARS-CoV-2 infection [19] . Notably however, no SARS-CoV-2 nucleic acid sequences were detected in eye conjunctiva in the current study. This may be related to the fact that no eye infection symptoms were evident in any of the patients in the study. SARS-CoV-2 RNA has been isolated from serum from SARS-CoV-2infected patients [20] , but no SARS-CoV-2 nucleic acid sequences were detected in plasma/blood samples in the current study. This may be because the concentration of SARS-CoV-2 nucleic acid in these samples was below the detection limits of the tests. In a recent study the SARS-CoV-2 nucleic acid detection threshold concentration of real-time RT-PCR was reportedly 1 × 10 3 copies/mL, which is considered to constitute inadequate sensitivity and insufficient stability [21] . In another report the false-negative rate of SARS-CoV-2 real-time RT-PCR was approximately 20%, and this led to serious consequences [5] . Chest CT was once considered better than real-time RT-PCR for COVID-19 screening, comprehensive evaluation, and follow-up in epidemic areas [21] . Given the need for timely and accurate COVID-19 diagnosis, it has become necessary to minimize possible causes of false-negative nucleic acid-based test results, or develop a new more sensitive nucleic acid detection-based assay. In the current study, of all respiratory tract sample types the detection rate in phlegm (66.7%) was the highest, and the detection rate in nasopharyngeal swabs (28.6%) was higher than that in oropharyngeal swabs (42.9%). This suggests that detection of SARS-CoV-2 is influenced by sample type. The rate of detection was greater in lower respiratory tract-derived samples than in upper respiratory tract-derived samples. Due to practical considerations, procedural factors, and comparative patient intolerance there are many difficulties associated with lower respiratory tract sampling. It has also been reported that nasopharyngeal aspirate had a higher positivity rate within 2 weeks of symptom onset, whereas combined nasal and oropharyngeal swabs were the least harmful to medical staff during sampling [22] . With regard to the environmental samples in the current study, the positivity rate of air samples was higher than that of surface samples. Environmental sampling results are influenced by the concentration of virus in the samples. 12 The low detection rate of real-time RT-PCR is associated with many factors including sampling procedures, nucleic acid quality, specimen source (upper or lower respiratory tract), and sampling timing (different periods of disease development). The quality of extracted nucleic acid has a strong influence on the outcomes of real-time RT-PCR. The template volume can be increased to raise the sensitivity of detection, and reagents containing guanidine salt can be used to inactivate virus as well as protect RNA [23] . To improve the positivity rate if lower respiratory tract specimens are unavailable, stool and blood samples can also be used at later stages of illness [23] . Nucleic acid tests are based on the concentration of virus, and serological tests using proteins can be utilized to supplement nucleic acid tests, enabling clinicians to track both sick and recovered patients, providing a better estimate of total SARS-CoV-2 infections [3] . Digital PCR has higher sensitivity and accuracy than standard real-time RT-PCR, and is developing rapidly and being widely applied in clinical microbiology, in fields such as drug resistance mutations in hepatitis C virus, Staphylococcus aureus, and influenza A virus [24] [25] [26] . To prevent false-negative SARS-CoV-2 nucleic acid-based test results, and develop a new sensitive detection assay, we evaluated the performance of real-time RT-PCR and digital PCR for detecting SARS-CoV-2 nucleic acid in clinical patient-derived samples and environmentally derived samples. A newly developed digital PCR assay was performed with samples that had previously been tested using real-time RT-PCR. All the real-time RT-PCR positive samples also tested positive in the digital PCR assay. Strikingly, digital PCR detected SARS-CoV-2 nucleic acids in several samples that had previously tested negative via real-time RT-PCR, including 3 patient-derived samples and 5 environmentally derived samples. These results suggest that digital PCR is a more efficient and sensitive method for SARS-CoV-2 detection than real-time RT-PCR. Digital PCR improved SARS-CoV-2 detection 13 In some recent studies reactivation of SARS-CoV-2 was evident in some recovered patients, and there were no specific clinical characteristics to distinguish them [27, 28] . In another study a recovered COVID-19 patient returned to being SARS-CoV-2-positive, raising concern about the present standards for patient discharge [29] . These observations indicate that a proportion of recovered patients may still be virus carriers. Stricter patient discharge standards and more sensitive detection assays are required to prevent the spread of SARS-CoV-2. Digital PCR can serve as a more sensitive nucleic acid detection assay. It can detect viral nucleic acid present at low concentrations. Thus, it has the potential to improve the detection rate in asymptomatic carriers. Digital PCR constitutes a fundamentally different approach to quantifying the number of DNA molecules in a sample, and quantification is achieved without the need for PCR cycle threshold values and standard curves [30] . In conclusion, digital PCR can be used in clinical applications as a new sensitive nucleic acid detection assay for SARS-CoV-2 in the future. Its use will reduce the rate of false-negative results, and improve the detection rate of asymptomatic carriers. We thank the patients and their families for participating in this study Communicating the Risk of Death from Novel Coronavirus Disease (COVID-19) Coronavirus Disease 2019 in China. The New England journal of medicine Diagnosing COVID-19: The Disease and Tools for Detection 2019-nCoV) by real-time RT-PCR. Euro surveillance : bulletin Europeen sur les maladies transmissibles = European communicable disease bulletin Clinical Data on Hospital Environmental Hygiene Monitoring and Medical Staff Protection during the Coronavirus Disease Sheng wu gong cheng xue bao = Chinese journal of biotechnology Improved Detection and Monitoring of Fungicide Resistance in Blumeria graminis f. sp. hordei With High-Throughput Genotype Quantification by Digital PCR New Approaches on Quantification of Campylobacter jejuni in Poultry Samples: The Use of Digital PCR and Real-time PCR against the ISO Standard Plate Count Method Droplet Digital PCR for Estimating Absolute Abundances of Widespread Pelagibacter Viruses Clinical management of severe acute respiratory infection (SARI) when COVID-19 disease is suspected Epidemiologic Features and Clinical Course of Patients Infected With SARS-CoV-2 in Singapore the General Administration of Quality Supervision IaQG. Hygienic standard for disinfection in hospitals Clinical features of patients infected with 2019 novel coronavirus in Wuhan Identification of a novel coronavirus causing severe pneumonia in human: a descriptive study Updated understanding of the outbreak of 2019 novel coronavirus (2019-nCoV) in Wuhan A familial cluster of pneumonia associated with the 2019 novel coronavirus indicating person-to-person transmission: a study of a family cluster Clinical Characteristics of 138 Hospitalized Patients With 2019 Novel Coronavirus-Infected Pneumonia in Wuhan Asymptomatic and Symptomatic Patients With Non-severe Coronavirus Disease (COVID-19) Have Similar Clinical Features and Virological Courses: A Retrospective Single Center Study Conjunctiva is not a preferred gateway of entry for SARS-CoV-2 to infect respiratory tract Inactivation of severe acute respiratory syndrome coronavirus 2 in plasma and platelet products using a riboflavin and ultraviolet light-based photochemical treatment Correlation of Chest CT and RT-PCR Testing in Coronavirus Disease 2019 (COVID-19) in China: A Report of 1014 Cases Zhonghua er bi yan hou tou jing wai ke za zhi = Chinese journal of otorhinolaryngology head and neck surgery Laboratory testing of SARS-CoV, MERS-CoV, and SARS-CoV-2 (2019-nCoV): Current status, challenges, and countermeasures. Reviews in medical virology Detection of Rare Drug Resistance Mutations by Digital PCR in a Human Influenza A Virus Model System and Clinical Samples Considerations for digital PCR as an accurate molecular diagnostic tool The Future of Digital Polymerase Chain Reaction in Virology Clinical characteristics of severe acute respiratory syndrome coronavirus 2 reactivation Positive RT-PCR Test Results in Patients Recovered From COVID-19 SARS-CoV-2 turned positive in a discharged patient with COVID-19 arouses concern regarding the present standard for discharge Digital PCR improved SARS-CoV-2 detection 17 Applications of Digital PCR for Clinical Microbiology This research was funded by the National Natural Science Foundation of China (nos. 30972610, 81273240, 91742107, and 81570002), National Key Research and Development Program (nos. 2017YFC0910000 and 2017YFD0501300), Jilin Province Science and Technology Agency (nos. The authors declare that they have no conflict interests.