key: cord-292031-weiwksh6 authors: Ramírez-Castillo, Flor Yazmín; Loera-Muro, Abraham; Jacques, Mario; Garneau, Philippe; Avelar-González, Francisco Javier; Harel, Josée; Guerrero-Barrera, Alma Lilián title: Waterborne Pathogens: Detection Methods and Challenges date: 2015-05-21 journal: Pathogens DOI: 10.3390/pathogens4020307 sha: doc_id: 292031 cord_uid: weiwksh6 Waterborne pathogens and related diseases are a major public health concern worldwide, not only by the morbidity and mortality that they cause, but by the high cost that represents their prevention and treatment. These diseases are directly related to environmental deterioration and pollution. Despite the continued efforts to maintain water safety, waterborne outbreaks are still reported globally. Proper assessment of pathogens on water and water quality monitoring are key factors for decision-making regarding water distribution systems’ infrastructure, the choice of best water treatment and prevention waterborne outbreaks. Powerful, sensitive and reproducible diagnostic tools are developed to monitor pathogen contamination in water and be able to detect not only cultivable pathogens but also to detect the occurrence of viable but non-culturable microorganisms as well as the presence of pathogens on biofilms. Quantitative microbial risk assessment (QMRA) is a helpful tool to evaluate the scenarios for pathogen contamination that involve surveillance, detection methods, analysis and decision-making. This review aims to present a research outlook on waterborne outbreaks that have occurred in recent years. This review also focuses in the main molecular techniques for detection of waterborne pathogens and the use of QMRA approach to protect public health. tracking [3, 8, 22] . In developing countries, the lack of financial and technological resources contributes to WBDOs [3] . Currently, it is estimated that there are 1407 species of pathogens infecting humans, which includes bacteria (538 species), viruses (208 types), parasitic protozoa (57 species), and several fungi and helminths species [2, 23] . The development of a disease, when and if infection to the host is produced, depends on factors such as minimal infectious dose (MID), pathogenicity, host susceptibility and environmental characteristics. Enteric bacteria have a MID in the range of 10 7 to 10 8 cells but it is much lower with some species, such as Shigella spp., (10 1 -10 2 ), Campylobacter spp., (about 500), E. coli O157:H7 (10 6 -10 8 ), and V. cholera (10 3 ) [2, 5] . Moreover, protozoan only need a few oocysts (10 1 -10 2 ) to produce the disease as well as the viruses which a small number of these are enough to develop a disease [2] . The protozoa Microsporidia, as the bacteria Mycobacterium avium intracellulare, Helicobacter pylori, Tsukamurella, Cystoisospora belli and viruses such as adenoviruses, parvoviruses, coronaviruses (SARS), and polyomavirus are some examples of the emerging potential waterborne pathogens [22, 24] . Furthermore, most of these organisms appear to have certain resistance against chlorine such as the microsporidia, Enterocytozoon bienusi, Encephalitozoon hellem and E. intestinales. M. avium and several viruses have resistance to common disinfectants for drinking water and to inactivation by UV light and heat [22] , which represents a higher challenge in the treatment to remove these pathogens from water sources. The major pathogens microorganisms in drinking water systems and their related diseases are listed in Table 1 . Presently, there is no unified method to encompass the collection and analysis of a water sample for all pathogenic microorganisms of interest [25] . The challenges of the detection methods are the physical differences between the major pathogen groups, low concentration of pathogens in a large volume of water which usually requires enrichment and concentration of the samples prior to detection processing, the presence of inhibitors from the sample (especially if it comes from polluted water), established general protocols for sample collection, culture-independent detection method, as well as detection of the host origin of pathogens [25] . The most important requirements for reliable analysis include: specificity, sensitivity, reproducibility of results, speed, automation and low cost [26] . Even though culture dependent methods are extensively used for pathogens detection in water, these methods are limited by their low sensitivity and the excessive time needed to obtain reliable results. Furthermore, since there is a broad environmental distribution of human pathogens that exist in a viable but non-culturable (VBNC) state such as E. coli, Helicobacter pylori and V. cholerae, false negative results may arise from culture dependent methods [27, 28] . In both culture and molecular methods, index pathogens for monitoring water quality have been selected in order to indicate the presence of a large amount of pathogens in water. Among these, E. coli ( Figure 1 ) has been extensively used due to the fact that detection methods for these pathogens are relatively easy and inexpensive; nonetheless, they may have the disadvantage of not providing information on their host origin and, sometimes, they do not correlate with other pathogens present in the water, such as the viruses and protozoa. Thus, water characterized as pathogen-free by monitoring E. coli, for example, may be contaminated with viruses or protozoa [31] . Molecular methods can be very specific for particular species and provide further phylogenetic information about pathogens [32] . These methods allow the use of alternatives indicators which easily relate with the host source. This permits the discrimination between human and animal pathogens and tracking the source of pollution [29, 31] . It has been suggested that host-origin libraries, based on a phenotypic methods, may be useful for tracking the pathogen source but the development of such libraries may incur a significant cost [8] . Therefore, molecular methods seem to better suited for health risk assessments. Nowadays, there are a number of different molecular methods to detect diverse pathogens. They are used to evaluate the microbiological quality of water, the efficiency of pathogens removal in drinking and wastewater treatment plants, and as microbial source-tracking (MST) tools [33] . Several examples of detection methods and their limits of detection are listed in Table 2 . Molecular techniques, such as nucleic acid amplification procedures, offer sensitive and analytical tools for detecting a variety of pathogens, including new emerging strains, present the possibility of automation, and real-time analysis to provide information for microbial risk assessment purposes [33] . Immunology-based methods E. coli O157:H7 and S. enterica typhimurium. 1.8 × 10 3 cfu/mL of E. coli and 9.2 × 10 3 cfu/mL of Salmonella Contaminated food. [61, 62] * GC logs are mean values of genome copy logs. Polymerase chain reaction (PCR) is one of the most commonly used molecular-based methods for detection of waterborne pathogens [28] . PCR operates by amplifying a specific target DNA sequence in a cyclic three-step process-denaturalization, annealing and extension-in order to achieve exponential amplification of the target sequence [63] . Several variations of PCR such as multiplex PCR (mPCR) allow simultaneous detection of several target organisms by coding specific genes of diverse pathogens in the sample in a single reaction. PCR method has the advantage of quick analysis. However, it necessitates accurate primers and optimal reaction mixture to avoid the risk of false positive and negative results [28, 33] . Limitations of DNA based methods such as PCR include the inability to discriminate between viable from non-viable cells that both contain DNA, the low concentration of several pathogens in water such as Cryptosporidium, Giardia and viruses, and the lack of data to indicate the real infectious risk to a population. Challenges of molecular techniques include: the need for water concentration methods (i.e., for virus, ultrafiltration and direct flocculation protocols are used as concentration methods), the presence of inhibitors in water samples including humid acids and metals, to which PCR is sensitive, and the reproducible purification techniques by DNA or RNA from heterogeneous samples. In addition, result validation is required, since as indicated by Hartman and co-workers [64] ; also, high sensitivity in molecular techniques introduces a high risk of false positive results. An example of mPCR includes the technique developed by Omar and Barnard [65] to detect the pathogenic and commensal E. coli from clinical and environmental water sources. To distinguish pathogenic E. coli from commensal, the presence of 11 genes was evaluated in environmental waters. In addition, as control to evaluate the sensitivity of the technique and the false negative due to PCR, inhibitors were controlled using mdh gene (malate dehydrogenase) and gapdh gene (glyceraldehyde-3phosphate dehydrogenase). Another variation of the PCR is quantitative real-time PCR (qPCR) which enables quantification of DNA targets by monitoring amplified products during cycling as indicated by increasing fluorescence [66] . This method provides high sensitivity and specificity, faster rate of detection, minimizes the risk of cross-contamination, and there is no need for a post-PCR analysis [67] . The dual-labeled fluorescent probes such as TaqMan probe and the fluorescent dye SYBR green are the most used techniques for detecting pathogens [68] . qPCR approach has been used to quantify human pathogens, such as E. coli O157:H7 [69] , and Campylobacter spp., [70] . These qPCR systems can specifically detect and quantify pathogens at concentrations as low as one target molecule per reaction. However, most of these methods can only detect and quantify one pathogen in a single reaction [71] . Ishii and co-workers [39, 71] designed a microfluidic qPCR by using TaqMan probes (hydrolysis probe-based qPCR) labeled with different fluorophores that can detect L. monocytogenes, V. cholerae, V. parahaemolyticus, Pseudogulbenkiana sp., S. typhimurium, S. flexneri, C. perfringens and pathogenic E. coli at levels of detection of 100 cells/L. Other advances in PCR include the microfluidics and nanobiotechnology field, allowing the construction of high-density and low-volume qPCR platforms, such as the OpenArray system that accommodates 3072 reactions per array [72] . qPCR protocols have also been developed for the detection and identification of Cryptosporidium spp., in river water with a lower quantitation limit of 2.5 oocysts/sample [42] . For detection of G. lamblia and G. ardeae in wastewater samples, qPCR reached a sensitivity of 0.45 cysts per reaction [73] . Moreover, because of the importance of biofilm coating pipes in drinking water systems, the detection of pathogens in microbial communities is important. L. monocytogenes has been investigated in biofilms by using qPCR techniques with a number of L. monocytogenes detected growing in biofilm of 6 × 10 2 cfu/cm 2 [45] . For RNA virus detection, quantitative reverse-transcriptase (qRT)-PCR was developed in order to provide quantitative estimation of the concentration of pathogens in water [74] . This technique has the advantages of detecting viable cells due to detect messenger RNA (mRNA), which is present only in viable organisms. However, damaged genomes may fail to be detected with this technique [32, 75] . Oligonucleotide microarrays are a powerful genomic technology that is widely utilized to monitor gene expression under different cell growth conditions, detecting specific mutations in DNA sequences and characterizing microorganisms in environmental samples [76] . DNA microarrays are arrays containing high density immobilized nucleic acids (genomic DNA, cDNA or oligonucleotides) in an ordered two-dimensional matrix that enables the simultaneous detection of hundreds of genes in a single assay via nucleic acid hybridization [77] . Microarrays are made up of glass slides or chips coated with specific oligonucleotide probes which are chemically synthesized short sequences (25 to 80 bp) [28, 78] . Microarray technology allows the rapid detection of multiple genes of multiple organisms simultaneously in the sample due its capacity for screening large numbers of sequences [32] , has high throughput capacity and is able to be automated. Therefore, large-scale and data-intensive experiments are performed in microarrays [4, 28] . Microarrays have also the ability to detect antimicrobial resistance to different antibiotics, and the probes could be designed for detecting the host origin of contaminants, which represents another advantage for characterization of contamination in water. However, advanced molecular technologies such as microarrays could experience difficulties distinguishing between viable and non-viable cells, have a relatively high cost, and may have non-specific hybridization resulting in a lower specificity and low sensitivity [32] . DNA microarray coupled with PCR amplification of target genes has been developed for higher sensitivity. Through these steps, signal sensitivity increased around 10 6 -fold [79] . Nonetheless, the PCR-microarray technique might lack sensitivity when the amount of sample is limited, since the technique requires splitting the samples into several PCR reactions to amplify [50] . DNA microarray in a two-step PCR-DNA microarray assay that first amplifies the 16S or 18S rRNA gene, respectively, followed by hybridization of these products onto a low-density DNA microarray was developed to detect most of the common waterborne protozoan pathogens including C. parvum, G. intestinalis, Acanthamoeba spp., Entamoeba histolytica, and Naegleria spp. [48, 49] . In 2002, Wilson and co-workers [46] were able to identify 18 pathogenic bacteria, eukaryotes and viruses by using species-specific primer sets to amplify multiple diagnostic regions unique to each individual pathogen in the microarray. Inoue and co-workers [80] studied the occurrence of 941 pathogenic bacterial species in groundwater and were able to distinguish between human and animal sources. Microarrays for detection of human enteric viruses in community wastewaters using cell culture coupled with multiple targets including DNA and RNA viruses have also been developed [81] . The ViroChip, a pan-virus DNA microarray containing thousands of 70-mer oligonucleotide probes to target all viral families to infect humans, has been described by Wang and co-workers [82] . Leski et al. [83] developed a high-density re-sequencing microarray that has the capability of detecting 84 different types of pathogens ranging from bacteria, protozoa, and viruses, including B. anthracis, Francisella tularensis and Ebola virus with limits of detection of 10 4 to 10 6 copies per test for nearly all the pathogens with high specificity. At present, standard and custom-made DNA microarrays are commercially available from companies such as Affymetrix, Corning and Agilent Technologies [84, 85] . One example of these is the phylogenetic microarray "PhyloChip" by Affymetrix which consists of 500,000 oligonucleotide probes capable of identifying 8743 strains of bacteria and Archaea [86, 87] . This technology is very powerful because most known bacteria can be detected in samples without culturing, and the sensitivity allows also the detection of lower-abundance organisms (detection limit of ~0.01% of microbial communities) [88] . Pyrosequencing is a DNA sequencing technology for short-read DNA sequencing that uses enzyme-couple reaction and bioluminescence to monitor the pyrophosphate release accompanying nucleotide incorporation, in real time [89] . Pyrosequencing technology provides a large number of sequences read in a single run [90] . In the pyrosequencing reaction, the enzymes DNA polymerase, ATP sulfurylase, luciferase and apyrase are needed. The nucleotides are added to form the complementary strand of the single-stranded template, to which a sequencing primer is annealed. During the nucleotide incorporation, the pyrophosphate (PPi) is released. ATP sulfurylase converts the PPi into ATP and the ATP is then converted to visible light by luciferase and the produced light signal is detected [87, 90] . The methodology includes a primary step of concentrating the water pathogens followed by a secondary concentration depending of the type of the pathogen. The third step involves DNA extraction (for bacteria and protozoa) and nuclease treatment (viral DNA/RNA extraction). Then, the DNA is amplified, the pyrosequencing is taking place and finally the analysis and bioinformatics can be performed [87, 90] . In recent years, a new whole genome amplification and sequencing approach called "Single Virus Genomics", which enables the isolation and complete genome sequencing by 454 pyrosequencing of the single virus particle, has been described [91] . Roche 454 pyrosequencing and other commercially available high-throughput sequencing platforms such as Solexa/Illumina Genome Analyzer, Applied Biosystem SOLiD Sequencing as well as the most recent, the Ion Torrent system, have revolutionized the study of microbial diversity [87] . Pyrosequencing could identify novel pathogens associated with water and address multiple etiologies. However, the DNA amount present in wastewater samples could limit the sensitivity of this tool as it requires DNA templates at picomole level but a much lower amount of DNA may be available in water samples. This technology is also limited by the cost, the complexity of analysis, the need for increasing availability of massive computing power and the efficiency of data generation [92] . Pyrosequencing has been used to the analysis of bacterial biofilm communities in water meters of a drinking water distribution system [93] , mixed urban watershed [94] , characterization of nontuberculous Mycobacterium communities in unchlorinated drinking water [95] , and the detection of bacteriophages in reclaimed and potable and lake waters [96] . FISH or fluorescence in situ hybridization is based on hybridization of the sample with rRNA oligonucleotide probes labeled covalently at one end with fluorescent dye. This technique allows an enumeration of particular microbial cells by the use of confocal microscopy, fluorescence microscopy or flow cytometry in order to obtain qualitative and quantitative results [97] . FISH is commonly used for the detection and identification of different microorganism in mixed populations such as in biofilms ( Figure 2 ) and has been used to produce a quantitative description of the microbial community structure in activated sludge and wastewater [79, 98] , to study mechanisms of survival, infection at cellular level and detection of emerging pathogens from water, sewage and sludge [79] . One example is the two-color FISH assay, based on species-specific probes for C. parvum (Cpar 677 probe) and C. hominis (Chom253 probe), and has been shown to distinguish between the two species of concern to public health [33, 99] . Several kits of FISH are now available in the market, one example of these are the commercial kit Label IT ® Fluorescence In Situ Hybridization Kit Cy ® 3, fluorescein and TM-Rhodamine, which optimized the preparation and hybridization of fluorescently labeled DNA probes [100] . Viable But Non-culturable (VBNC) cells could detected by FISH couple with direct viable count (DVC) assay [101] [102] [103] . In the assay, the cells are cultured in reach media with antibiotics which prevent cellular division, increases of intracellular rRNA and allow the elongations of viable cells. FISH is made with specific probes that target 16rRNA labeled with fluorescent dye. The sample is stained by 4,-diamino-2-pheynyl indole (DAPI) that is bound to double-stranded DNA to count the total amount of cells in the samples, and the results are compared to culture methods to measure the proportion of VBNC cells [103] . Members of the family Enterobacteriaceae and E. coli in drinking water systems, freshwater and river water have been detected by this tool [103] . This assay is able to detect 3000 viable E. coli/100 mL in more than 10 8 non-E. coli/100 mL [103] . However, the technology is limited by a low sensitivity, and the necessity of pre-enrichment and concentration steps [33] that also may increase inhibitor concentrations and lead to false negative results [32] . VBNC cells are living cells, metabolically active, that may still retain or regain their virulence potential upon the resuscitation (return to culturable state) under favourable environmental conditions or when the stress is removed [104] [105] [106] [107] . Due to the fact that VBNC cells cannot be identified by culturable methods, the number of pathogens in this state could be underestimated and, if all bacteria in the sample are in VBNC state, the sample may be regarded as pathogen-free due to non-detection [105] . The conversion to the VBNC state is supposed to be a response to adverse environmental conditions [105] [106] [107] . Resuscitation of these species could be triggered by a variety of stimuli, such as rich medium, an increase in temperature, and the presence of host cells. Factors as the strain used, the age of VBNC cells, and the conditions that induced the VBNC state also affect the resuscitation [105, 108, 109] . Besides FISH, other tools to detect VBNC bacteria includes: immunological techniques; RT-PCR, which target the mRNA that indicates the presence of viable cells that carry out transcription; DNase I protection assay, since only the viable cells have intact membranes to protect genomic DNA from digestion by exogenous nucleases; enzymatic activity, as viable cells carry out metabolic reactions and respiration; bacteriophage-based assay, using a combination of fluorescence intensity and nutrient uptake analysis; as well as the commercial kit LIVE/DEAD ® BacLight TM assay to distinguish viable cells from dead cells based on the membrane integrity [102] [103] [104] [105] [106] [107] [108] [109] . Immunological detection with antibodies is a technology that has been employed for the detection of multiple pathogens [110, 111] . These methods are based on antibody-antigen interaction, whereby a particular antibody will bind to specific antigen which comprise the use of polyclonal and monoclonal antibodies [28, 63] . Immunological detection includes, for example, serum neutralization tests (SNT), immunofluorescence, and enzyme-linked immunosorbent assays (ELISA). SNT test has been used for the serotyping of viruses and involves mixing a sample, extracted from a plaque assay, with antiserum and then assessing the decrease of infectivity by plaque assay [112] . Assays based on immunofluorescence and immunomagnetic separation (IMS) are used to detect protozoan parasites. The US Environment Protection Agent (EPA) has established method 1623.1 for the combined detection of Cryptosporidium spp. and Giardia spp., or method 1622 for Cryptosporidium spp., both of which use IMS followed by immunostaining and fluorescent microscopy [113, 114] . Nevertheless, limitation such as low sensitivity, false negative results, cross-reactivity with closely related antigens and the need for a pre-enrichment in order to reduce the cell surface antigens, are present in these techniques [33] . Biosensor based methods have flourished in recent years. Biosensor is an analytical device that consists of a bioreceptor that recognizes the target analyte (e.g., enzymes, antibodies, nucleic acids, cell receptors, aptameters, recombinant antibodies, imprinted polymers and synthetic catalyst) and a transducer that converts the biological interactions into a measurable electrical signal (optical, electrochemical, mass-based, thermometric, or micromechanical) [26, 33, 112] , thereby providing selective quantitative or semiquantitative analytical information [114] . Optical biosensors rely on a change in the optical properties of the surface caused by the binding of the analytes used for detection [114] . Electrochemical biosensors are based on measuring changes in conductance, resistance or capacitance of the active surface. In these devices, one of the electrodes is immobilized with a recognition molecule. When analytes bind, a change in electrical properties occurs providing the sensor signal [115, 116] . Mass-sensitive biosensors include quartz crystal microbalance biosensor, which uses a quartz crystal inserted in two electrodes. As quartz is piezoelectric (used for wave propagation), the crystal can be excited by applying a voltage across the electrodes and will exhibit a resonance frequency [115, 117] . Biosensor methods have the advantages of automation and miniaturization of biological analytical techniques, have short analysis times, portability, real-time measurements and do not require sample pre-enrichment [117] . Nevertheless, problems such as great sensitivity to pH, change of mass, temperature, etc., represent a great challenge to the use of these methods [115] . In 2005, Taylor and co-workers [118] used the surface plasmon resonance (SPR) detection with pretreatment of the bacteria (heat or ethanol treated or detergent-lysed cells) and the antibodies goat anti-E.coli O157:H7 polyclonal antibody (PAb) and mouse anti-E. coli O157:H7 monoclonal antibody (MAb) for signal amplification to obtain a limit of detection (LOD) of 10 4 cfu/mL. Antibody-based indirect sensor (optical biosensor) for Escherichia coli O157:H7 with fluorescent labeling was reported by Ho et al., [119] in 2004 to reach a LOD of 360 cells/mL. Detection and monitoring of pathogens in water continues to be a field with constant improvement and development of new tools that will permit relative low cost assays and rapid identification of multiple pathogens with limits of detection that meet regulatory goals. Nevertheless, efforts to standardize techniques in the field have to include sample collection, sample concentration, sample purification, sample processing, analysis, and data collection are still remaining [3] . Sample collection has to be standardizing mainly if the target is on biofilms. Validation of new emerging techniques has also to be completed. Besides microarrays and biosensors, the integration of molecular technologies is promising. "Lab-on-chip" (LOC) represents an integration of sensors and microfluidic systems in a miniaturized tool that could archive real-time monitoring of samples [120] . By this way, LOC integrates several laboratory functions on a single chip and reduced sample and reagent consumption is automatized and has fast detection times and low limits of detection. However, there are still challenges related to developing practical LOC components, assay procedures and validation of the on-chip detection approaches, and of course, the different scenarios that represent a water sample [121] . Since outbreaks continue to occur despite water quality monitoring, a new approach has been applied to solve the need for a conceptualization of risk and to provide guidance and legislations [122] . Quantitative microbial risk assessment (QMRA) is a systematic quantitative assessment process to estimate the health risks or illness rates of human exposure to particular pathogens. The approach combines dose response information for the infectious agent with information on the distribution of exposures routes and is able to demonstrate if the health targets are met in a drinking water distribution system [123] , which are suggested to be a health risk less than one infection per 10,000 individuals per year, or, a disease burden of 10 −6 disability adjusted life year (DALY) per person per year [3] . This tool helps to predict the burden of waterborne diseases, set tolerable limits of waterborne disease, identify the means to reduce the risk to the consumers and determine measures to protect water safety [2] . Risk assessments involve five steps ( Figure 3 ) [2, [124] [125] [126] [127] . (i) Hazard identification: consists in the identification and quality evaluation of the microbial hazard. This step takes into account the potential outcomes (health effects, disease outbreaks), pathogen properties (virulence, adaptation, resistance, and mutation) and hazard pathways; (ii) Exposure assessment: is the estimation of the duration of human exposures to pathogens by specific routes, the determination of the size and nature of the population exposed and the barrier reduction and recontamination on water; (iii) Dose-response assessment is the characterization of the relationship between dose and incidence of adverse effect in populations exposed to microbial pathogens. It comprises data of illness, secondary transmission and immunity in population. Typically, the dose-response is derived from studies of exposure of human volunteers to different doses of the pathogen or is based on previous outbreaks [127] [128] [129] . Factors influencing the dose-response are the exposure route, exposure medium pathogen strain host endpoint and the data source. Two commonly models are the beta-Poisson model and the exponential model, described elsewhere [2, 125, 130] ; (iv) Risk characterization is the integration of information from hazard identification, dose-response assessment, and exposure assessment to estimate the magnitude of health effects; (v) Risk management and communication is a decision-making process based in all previous steps in risk assessment [2, [125] [126] [127] [128] . In QMRA, the different variants contribute to measuring the health risk but also introduce variability corresponding to dose-response sensitivity, detection methods, temporal and spatial heterogeneities in pathogen densities and uncertainty (i.e., unrepresentative population, modeling pathogen densities and knowledge of dose-response relationships) [124, [130] [131] [132] . The advantage of probabilistic modeling is to distribute the uncertainties through the model [133] . The QMRA approach presents potential advantages and limitations of risk management options that could be evaluate by numerical stimulations to investigate their possible efficacy, and that risk below epidemiologically detectable levels may be estimated under specific circumstances [134] . However, the greatest limitation on QMRA is the lack of available data to carry out this assessment [134] . QMRA also depends on the method used for monitoring pathogens in water. Actually, QMRA approach is based exclusively on data obtained by cultivation methods, which are not allowing the complete characterization of risk, since as mentioned above, many waterborne microorganisms are not culturable or are inefficiently cultured, thus leading to underestimation of pathogens in water. Therefore, selecting the optimal tool for pathogen monitoring in source water that gives the necessary information on occurrence, prevalence, virulence, and even viability of the pathogens influences the results of the QMRA approach. Polymerase chain reaction methods provide rapid detection of microorganisms but are complicated by the presence of inhibitory compounds in the sample and the detection of viable but non-culturable as well as non-viable pathogens. Integrating the culture and PCR methods may help to overcome the weakness of each individual method [133, 135, 136] . As mentioned before, current risk characterization approaches rely on detection of microbial indicators or "index pathogens", which does not accurately predict the occurrence of all pathogens. Novel markers that better predict the presence of all pathogens of interest would improve risk assessment and management actions [31, 123] . Alternative indicators proposed are Bacteroidales and Lachnospiraceae, which are rich in host-specific bacterial organisms [31, 137] , faecal bacteriophages, rotavirus, Ascaris [138] , Firmicutes [31] , Bifidobacteria spp. [139] , and Methanobrevibacter smithii [140] . Commonly 16S rRNA gene has been used as a marker to track host-specific organisms [31] , but other authors such as Villemur et al. [141] and Caldwell et al. [142] suggest the use of DNA (mtDNA) to target the identification of human and animal origins. QMRA has been used to estimate the health risk associated with bathers after surfing and swimming in dry weather and post-storm conditions near beaches [143] [144] [145] , water distribution networks [146] , recreational waters impacted by agricultural contamination [122, 147] , and assessment of the efficiency of the applied treatment processes in drinking water [143] . Such investigations reinforce the need for preventive measures, such as those designed to prevent and take measures to reduce water contamination. A computational tool for quantitative microbial risk assessment, called QMRAspot, was developed for rapid and automatic undertaking of QMRA for drinking water. QMRAspot uses four index pathogens: Campylobacter, enterovirus, Cryptosporidium, and Giardia [143] . Also, a software infrastructure name FRAMEs (Framework for Risk Analysis in Multimedia Environmental Systems) have been created to assess the water health risk which allows describing the problem statement, integrating models and data-bases, and provides the infrastructure for performing sensitivity, variability and uncertain analyses [131] . It is clear that QMRA and management of water quality are important tools for governmental regulation and scientific analysis. Nevertheless, it is also clear that these tools still are not adopted widely [123] . Efforts to encourage the use of the QMRA approach have to be made to support implementation of water safety plans, improve understanding of vulnerabilities of drinking water distribution systems, assess risks associated with extreme events and establish the best management option for the given risk in order to ensure water safety [3] . Waterborne pathogens are a global concern for worldwide public health. Since pathogens in water are still a major cause of severe illness and mortality, the control, monitoring and application of regulations for water quality are in urgent need and must incorporate more effective microbiological monitoring, pathogen detection and health risk assessment in order to reach the goal of pathogen-free water. Although culture methods for detection of pathogens in water are used routinely, they may underestimate the level of microbial pathogens. Molecular techniques improve the characterization of these pathogens; however, several disadvantages such as the lack of standardization of protocols and sample processing are still a challenge. Improving available technologies so that they are able to identify causative agents more accurately and in a shorter amount of time, to detect viable microorganisms and characterize them according to microbial communities and that enable the creation of accessible data could enhance the knowledge of waterborne pathogens and the possibilities to predict pathogen contamination and protect public health. Pathogen indicators need to be continually improved since a large number of new emerging pathogens are causing water-related diseases and waterborne outbreaks. The implementation of QMRA needs to be adapted to estimate the level of risk from different pathogens for better understanding of the dynamics of microbial populations in drinking water systems, and to identify the most effective strategies to be implemented to reduce the health risk and to improve water quality. World Health Organization (WHO) Microbiology of Drinking Water Production and Distribution Microbes in Pipes: The Microbiology of the Water Distribution System A Report on an American Academy of Microbiology Colloquium Recommended advanced techniques for waterborne pathogen detection in developing countries Dei-Cas, E. Microbial agents associated with waterborne diseases Global Water, Sanitation, and Hygiene (WASH) Progress on Sanitation and Drinking-Water Contamination of water resources by pathogenic bacteria Millennium Development Goals: Progress towards the Health-Related Millennium Development Goals Waterborne outbreaks reported in the United States Causes of outbreaks associated with drinking water in the United States from A fatal waterborne disease epidemic in Walkerton, Ontario: Comparison with other waterborne outbreaks in the developed world Surveillance for waterborne disease outbreaks associated with drinking water and other nonrecreational water-United States Epidemiology of cholera in the Philippines The 2010 cholera outbreak in Haiti: How science solved a controversy Lessons learned during public health response to cholera epidemic in Haiti and the Dominican Republic Shiga toxin-producing Escherichia coli O104:H4: A new challenge for microbiology Annual Epidemiological Report Food-and Waterborne Diseases and Zoonoses Self-reported diarrhea in a control group: A strong association with reporting of low-pressure events in tap water Global Drinking Water Management and Conservation Optimal Decision-Making Surveillance for waterborne-disease outbreaks associated with drinking water--United States Emerging waterborne pathogens: Can we kill them all? Where do emerging pathogens come from? Microbe Guidelines fror Drinking Water Quality-Volume 1: Recommendations; World Health Organization (WHO): Geneva, Switzwerland Towards a unified system for detecting waterborne pathogens Microarray analysis reveals the actual specificity of enrichment media used for food safety assessment Advances in rapid detection methods for foodborne pathogens Rapid methods for the detection of foodborne bacterial pathogens: Principles, applications, advantages and limitations Water microbiology. Bacterial pathogens and water Water and infection: Epidemiological studies of epidemic and endemic Waterborne Disease Discovering new indicators of fecal pollution Molecular Methods for the Detection of Waterborne Pathogens Bofill-Mas, S. Molecular detection of pathogens in water--the pros and cons of molecular techniques Development and use of 16s rRNA gene targeted PCR primers for the identification of Escherichia coli cells in waters Rapid culture-independent quantitative detection of enterotoxigenic Escherichia coli in surface waters by real-time PCR with molecular beacon An assay combining cell culture with reverse transcriptase PCR to detect and determine the infectivity of waterborne Cryptosporidium parvum Co-detection of five species of water-borne bacteria by multiplex PCR Quantitative real-time PCR assays for detection of human adenoviruses and identification of serotypes 40 and 41 Water quality monitoring and risk assessment by simultaneous multipathogen quantification Microfluidic quantitative PCR for simultaneous quantification of multiple viruses in environmental water samples Real-time PCR and NASBA for rapid and sensitive detection of Vibrio cholerae in ballast water Quantification and genotyping of Cryptosporidium spp. in river water by quenching probe PCR and denaturing gradient gel electrophoresis Real-time PCR for quantification of Giardia and Cryptosporidium in environmental water samples and sewage Quantification of human astroviruses in sewage using real-time RT-PCR Quantitative detection of Listeria monocytogenes in biofilms by real-time PCR Sequence-specific identification of 18 pathogenic microorganisms using microarray technology Waterborne pathogen detection by use of oligonucleotide-based microarrays DNA microarray-based detection and identification of waterborne protozoan pathogens Development and application of an oligonucleotide microarray and real-time quantitative PCR for detection of wastewater bacterial pathogens Detection of multiple waterborne pathogens using microsequencing arrays Rapid detection and antimicrobial resistance gene profiling of Yersinia pestis using pyrosequencing technology Rapid detection and identification of Bacillus anthracis in food using pyrosequencing technology A microbiology-based multi-parametric approach towards assessing biological stability in drinking water distribution networks Development of a Cryptosporidium oocyst assay using an automated fiber optic-based biosensor Highly sensitive and specific detection of viable Escherichia coli in drinking water Amperometric immunosensor for the detection of Vibrio cholerae O1 using disposable screen-printed electrodes Development of evanescent wave all-fiber immunosensor for environmental water analysis Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples Fluorescent in situ hybridization: A new tool for the direct identification and detection of F. psychrophilum Quantification of target molecules needed to detect microorganisms by fluorescence in situ hybridization (FISH) and catalyzed reporter deposition-FISH Immunomagnetic separation combined with real-time reverse transcriptase PCR assays for detection of norovirus in contaminated food Optical enzyme-linked immunosorbant assay on a strip for detection of Salmonella typhimurium Methods for rapid detection of foodborne pathogens: An overview Development of a novel internal positive control for Taqman based assays Detection of diarrhoeagenic Escherichia coli in clinical and environmental water sources in South Africa using single-step 11-gene m-PCR The power of real-time PCR A new platform for real-time PCR detection of Salmonella spp., Listeria monocytogenes and Escherichia coli O157 in milk Comparison of different approaches to quantify Staphylococcus aureus cells by real-time quantitative PCR and application of this technique for examination of cheese Multiplex fluorogenic real-time PCR for detection and quantification of Escherichia coli O157:H7 in dairy wastewater wetlands A real-time multiplexed PCR assay for rapid detection and differentiation of Campylobacter jejuni and Campylobacter coli Simultaneous quantification of multiple food-and waterborne pathogens by use of microfluidic quantitative PCR Biotrove Open Array System Improved specificity for Giardia lamblia cyst quantification in wastewater by development of a real-time PCR method Detection, quantitation and identification of enteroviruses from surface waters and sponge tissue from the florida keys using real-time RT-PCR Detection of viable oocysts of Cryptosporidium parvum following nucleic acid sequence based amplification Microarrays for bacterial detection and microbial community analysis DNA microarrays: A powerful genomic tool for biomedical and clinical research Advances in DNA microarray technology for the detection of foodborne pathogens Molecular techniques in wastewater: Understanding microbial communities, detecting pathogens, and real-time process control High-throughput DNA microarray detection of pathogenic bacteria in shallow well groundwater in the Kathmandu Valley Detection and characterization of human pathogenic viruses circulating in community wastewater using multi target microarrays and polymerase chain reaction Viral discovery and sequence recovery using DNA microarrays Testing and validation of high density resequencing microarray for broad range biothreat agents detection Performance of the Affymetrix GeneChip HIV PRT 440 platform for antiretroviral drug resistance genotyping of human immunodeficiency virus type 1 clades and viral isolates with length polymorphisms Technical assessment of the Affymetrix yeast expression GeneChip ye6100 platform in a heterologous model of genes that confer resistance to antimalarial drugs in yeast Phylochip microarray analysis reveals altered gastrointestinal microbial communities in a rat model of colonic hypersensitivity Detection of pathogens in water: From phylochips to qPCR to pyrosequencing High-density universal 16S rRNA microarray analysis reveals broader diversity than typical clone library when sampling the environment Pyrosequencing: History, biochemistry and future Pyrosequencing as a tool for better understanding of human microbiomes Single virus genomics: A new tool for virus discovery Pyrosequencing enhancement for better detection limit and sequencing homopolymers Pyrosequencing analysis of bacterial biofilm communities in water meters of a drinking water distribution system Potential human pathogenic bacteria in a mixed urban watershed as revealed by pyrosequencing Pyrosequence analysis of the hsp65 genes of nontuberculous Mycobacterium communities in unchlorinated drinking water in the Netherlands Metagenomic analysis of RNA viruses in a fresh water lake Use of flow cytometry to monitor Legionella viability Fluorescence in situ hybridisation for the identification and characterisation of prokaryotes Development of a two-color fluorescence in situ hybridization technique for species-level identification of human-infectious Cryptosporidium spp Mirus. Label. IT Fluorescence In Situ Hybridization Kits Detection and identification of specific bacteria in wound biofilms using peptide nucleic acid fluorescent in situ hybridization (PNA FISH) Biofilms in drinking water and their role as reservoir for pathogens Enumeration of viable E. coli in rivers and wastewaters by fluorescent in situ hybridization The Public Health Significance of Viable but Nonculturable Bacteria The importance of the viable but non-culturable state in human bacterial pathogens Recent findings on the viable but nonculturable state in pathogenic bacteria Viable but non-culturable forms of food and waterborne bacteria: Quo vadis? Influence of copper ions on the viability and cytotoxicity of Pseudomonas aeruginosa under conditions relevant to drinking water environments Resuscitation of Escherichia coli VBNC cells depends on a variety of environmental or chemical stimuli A review of molecular recognition technologies for detection of biological threat agents An overview of foodborne pathogen detection: In the perspective of biosensors Biosensors for the detection of waterborne pathogens Method 1623.1: Cryptosporidium and Giardia in Water by Filtration/IMS/FA Method 1622: Cryptosporidium in Water by filtration/ims/fa Biosensors for the Detection of Waterborne Pathogens The Coming Together of the Sciences: Biosensors for the Detection of Waterborne Pathogens Using antibodies and Gene-Based Recognition Chemistries Recent advances in bacteriophage based biosensors for food-borne pathogen detection Comparison of E. coli O157:H7 preparations methods used for detection with surface plasmon resonance sensor Liposome-based microcapillary immunosensor for detection of Escherichia coli O157:H7 Recent developments in optical detection technologies in lab-on-a chip devices for biosensing applications. Sensors (Basel) Lab-on-a-chip pathogen sensors for food safety Predicting pathogen risks to aid beach management: The real value of quantitative microbial risk assessment (QMRA) A comparative analysis of current microbial water quality risk assessment and management practices in British Columbia and Ontario Quantitative Microbial Risk Assessment Assessment of risk Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) and U.S. Environmental Protection Agency (EPA) EPA Publication: USA Hierarchical dose response of E. coli O157:H7 from human outbreaks incorporating heterogeneity in exposure Assessing pathogen risk to swimmers at non-sewage impacted recreational beaches Risk assessment for Cryptosporidium: A hierarchical bayesian analysis of human dose response data Modelling bacterial growth in quantitative microbiological risk assessment: Is it possible? Quantitative Microbial Risk Assessment of Waterborne Disease Guidelines for Safe Recreational Water Environments Volume 1 Coastal and Fresh Waters Use of integrated cell culture-PCR to evaluate the effectiveness of poliovirus inactivation by chlorine ICC/PCR detection of enteroviruses and hepatitis a virus in environmental samples Treated wastewater effluent as a source of microbial pollution of surface water resources Application of quantitative microbial risk assessment to analyze the public health risk from poor drinking water quality in a low income area in Accra Bifidobacterial diversity and the development of new microbial source tracking indicators A real-time qPCR assay for the detection of the nifH gene of Methanobrevibacter smithii, a potential indicator of sewage pollution An environmental survey of surface waters using mitochondrial DNA from human, bovine and porcine origin as fecal source tracking markers Mitochondrial multiplex real-time PCR as a source tracking method in fecal-contaminated effluents QMRAspot: A tool for quantitative microbial risk assessment from surface water to potable water Comparison of recreational health risks associated with surfing and swimming in dry weather and post-storm conditions at Southern California beaches using quantitative microbial risk assessment (QMRA) Microbial risks associated with exposure to pathogens in contaminated urban flood water QMRA in drinking water distribution system Estimated human health risks from exposure to recreational waters impacted by human and non-human sources of faecal contamination The authors would like to thank Pathogens Editors and the reviewers for their helpful comments. We are gratefully acknowledge the fie grate support of the Natural Sciences and Engineering Research Council of Canada (to J.H, RGPIN-25120) and from-Fonds de la recherche du Québec en Nature et Technologies (Centre de Recherche en Infectiologie Porcine et Avicole, CRIPA-Regroupements stratégiques RS-170946) and from the DFAIT Canada's Emerging leaders in the Americas program. We thanks to the CONACyT mixed scholarship (373176/246884) of F.Y.R.C., and to A.L.G.B., F.J.A.G. and the Universidad Autónoma de Aguascalientes for their funds. Josée Harel had the original idea for the manuscript and, with all co-authors, carried out the design. Flor Yazmín Ramírez-Castillo drafted the manuscript, which was revised by all authors. Abraham Loera Muro and Mario Jacques included the fluorescence in situ hybridization detection of Actinobacillus pleuropneumoniae isolated from water sources. Philippe Garneau critically revised the manuscript and verified the detection methods. Josée Harel, Mario Jacques, Alma Lilián Guerrero-Barrera and Francisco Javier Avelar-González revised all the manuscript and profit it. All authors read and approved the final manuscript. The authors declare no conflict of interest.