key: cord-353698-gj8sx3zy authors: Bibiano-Guillen, C.; Arias-Arcos, B.; Collado-Escudero, C.; Mir-Montero, M.; Corella-Montoya, F.; Torres-Macho, J.; Buendía-Garcia, M.J.; Larrainzar-Garijo, R. title: Adapted Diving Mask (ADM) device as respiratory support with oxygen output during COVID-19 pandemic date: 2020-10-28 journal: Am J Emerg Med DOI: 10.1016/j.ajem.2020.10.043 sha: doc_id: 353698 cord_uid: gj8sx3zy nan At the end of 2019, several cases of pneumonia were identified in Wuhan (Hubei, China) [1], caused by a new Orthocoronavirinae, commonly known as coronavirus, from the Coronaviridae family. In January 2020, there was a public health emergency declaration [2] and, as of March 2020, a pandemic [3, 4] . At present, more than 2 million cases have been confirmed globally (2.160 .2017 April 18th) [5] [6] [7] [8] [9] . In Spain, the first spots of epidemiological interest were identified in Madrid. Some of them were registered in the sanitary region where both Hospital Universitario Infanta Leonor and Virgen de la Torre Hospitals belong. The first PCR-positive patient was detected on March 4 th . After two weeks, on 18 th March, the number of positive cases increased to 302, and 41 patients died. By 1 st April, one month after the outbreak, the total number of cases was 1714. These data confirmed the explosive progression of the pandemic and the high mortality of patients who were hospitalized and made it necessary to implement several and different therapeutic measures to try and revert the catastrophic progression of this infection. The most extended therapeutic approach for COVID-19 is based on two main strategies [10] [11] [12] [13] : pharmacological treatment directed toward several physiological targets (viremia, immunological reactions, prothrombotic reactions) and hemodynamic and respiratory support with positive end-expiratory pressure (PEEP) in addition to mechanical ventilation. This is vitally necessary until pharmacological treatment or patient immune responses become effective. China and Italy have already described that acute respiratory distress syndrome (ARDS) is the most common manifestation in the clinical course of COVID-19 pneumonia [11] [12] [13] [14] ; however, this syndrome has a different progression than other J o u r n a l P r e -p r o o f respiratory diseases. The first-choice treatment for ARDS is mechanical ventilation (MV) with the use of orotracheal intubation (OTI). The ARDS mortality rate is over 50%, and the delay in this procedure is related to an even worse prognosis [15, 16] . The main limiting factors that healthcare systems must face when handling these critical patients are the limited access to ventilators and ICU resources and the fact that they are already overwhelmed by massive hospitalization due to respiratory distress and OTI needs [17, 18] . This is why current lines of work are focused on developing respiratory support alternatives that will gain time or allow the maintenance of an acceptable respiratory status until patients can access the ICU [19, 20] . In the absence of approved mechanical devices, such as continuous positive airway pressure (CPAP), positive end-expiratory pressure (PEEP) devices are being used [14, 16, 21] . In this paper, we describe our experience with the adaptation of diving masks (Figure 1 ) and predesigned and 3D-printed pieces (Annex) that work as respiratory PEEP valves and high-flow oxygen connectors. During the inspiratory phase, oxygen reaches the fitted mask via a high-flow tube connected to a flowmeter at an outlet on a high-pressure hospital circuit or in a portable oxygen bottle. The residual volume of the mask becomes a reservoir. During the expiratory phase, the PEEP valve resists airflow. The exhaled air flows decontaminated through an N99 high-efficiency filter, reducing the possibility of contagion by viral aerosolization. The main objective was to assess the efficacy of this alternative prototype for respiratory support in the context of the COVID-19 pandemic. The secondary outcomes were the clinical profiles of patients who could benefit from this device, as well as the safety parameters and potential adverse events. A descriptive case series study of twenty-five patients with acute respiratory syndrome secondary to SARS-CoV2 infection was performed at a Spanish center, Hospital Universitario Infanta Leonor of Madrid, between March 30 and April 18, 2020. We tested the Easybreath First-generation Snorkel Mask (Decathlon©) adapted with 3Dprinted appliances as a respiratory support device with oxygen output and a PEEP valve. All patients provided written informed consent, and the study was approved by the Hospital Committee for Medical and Health Research Ethics. There were a total of twenty-five patients: twenty-one men and four women. The demographics, baseline characteristics and comorbidities are shown in Table 1 . We established two clinical settings for the use of an adapted diving mask (ADM) at the emergency department: 1. Patients with an oxygen saturation under 93% and oxygen reserve to 15 L. 2. Patients using Pulmodyne® CPAP who presented with mild to severe intolerance to their interface or with an oxygen saturation under 92% despite maximum oxygen airflow. The mask was used with interrupted discontinuous character only to feed or hydrate the patient, aspirate secretions, if necessary, and administer artificial tears in the case of dry eye. In the absence of this nursing care, the patient was advised to maintain mask therapy for as long as possible. Severe clinical status was established when radiographic pulmonary alterations and serologic alterations such as lymphocyte count, transaminases, LDH and D-dimer were present. To assess the initial response of patients, we analyzed two variables: 1. Oxygen saturation improvement by comparing previous measurements and those immediately after oxygen saturation to the use of the mask. a. Qualitative variable: at least a 3-point improvement in oxygen saturation (yes/no). b. Continuous variable: improvement in mean-score mean from pre-mask saturation values. 2. Arterial blood gas analysis (ABGA) at one hour. Gas parameters were measured after one hour of mask use. To assess patient improvement, we used the following variables: The medical records of patients were analyzed by the research team of the Emergency Department, Hospital Universitario Infanta Leonor, Madrid. Epidemiological, clinical, laboratory, radiological and treatment outcome data were obtained via data collection forms from the electronic medical records. The data were reviewed by a trained team of physicians. The recorded information included demographic data, medical history, exposure history, underlying comorbidities, symptoms, signs, laboratory findings, and treatment measures. Descriptive statistical analysis was performed using IBM SPSS Statistics version 22 software (IBM Corporation USA). In this case series, the most common radiological pattern was the bilateral interstitial pattern (92,85%), followed by the multilobular pulmonary consolidation pattern (7.14%). A total of 3.57% of patients had less than 1500/µL lymphocytes, 85.7% had less than 150000/µL platelets, 78.5% had over 250 LDH U/L, 46.4% had D-dimer levels above 500 ng/mL, and 82.1% had a GOT over 40 U/L. The mean baseline oxygen saturation on admission was 83.6%, distributed in severity ranges as shown in Table 2 . There were two patients who had missing data. The distribution of patients according to the clinical setting is described in Table 2 . ADM use was higher in patients with an oxygen saturation under 93% with reservoir masks at 15 lpm (18 patients). Oxygen saturation was measured before initiating ADM therapy. The mean value was 90.24 %, and the patient distribution was made according to severity at saturation levels, as shown in Table 2 . After ADM initiation, patients had a very positive initial response ( Table 3 ). The immediate saturation value after ADM placement was 95.8%. In twenty-one patients, the saturation improvement was 3 or higher. The mean pO2 after one hour of ADM treatment was 93.75 mmHg, as measured by arterial ABGA (in five patients, we were not able to collect these data), the mean pCO2 was 40.91 mmHg, and all patients surpassed the 50 mmHg limit. Table 4 shows the different variables used to analyze the improvement in the intervention and the mean value of all oxygen saturation measurements for all days that ADM therapy was used in those patients who prolonged its time of use. More than 50% of patients tolerated the mask for 24 hours, switching to 3-hour minimum rotational use in combination with other therapies or devices. The main cause of ADM cessation was physical intolerance (nine patients). Eight patients needed invasive mechanical ventilation due to disease progression. Finally, five patients experienced clinical respiratory improvement. During the time of the study, eight patients died, five of whom were dismissed for ICU admission for prevalent comorbidities and advanced disease stage. Three of the patients who were admitted to the ICU for invasive mechanical ventilation died. There were no adverse events related to oxygen system failure during clinical use of the ADM device or any eye or skin adverse events. Four patients presented with isolated mild hypercapnia (pCO2 > 45 mmHg<5° mmHg) during ADM use, two of whom presented in the first hour of therapy and two during the ADM rotation period with other therapies and interfaces, without any additional clinical or analytical repercussions. The mask was not indicated in any patients who, in their baseline situation, already had hypercapnia of any degree or respiratory acidosis. One patient presented with respiratory acidosis (pH <7.35) and moderate hypercapnia (pCO2> 50 mmHg) during mask use. This patient was not considered for ICU care due to late disease progression and poor respiratory dynamics, which ended in death a few hours later (Table 5 ). The adapted Easybreath™ system is an efficient and safe alternative for respiratory support in the shortage of official devices in the current state of the pandemic. It has already been described that COVID-19 disease has two differentiated phases: initial pulmonary alveolar affectation caused by viral access to AC2 receptors [22, 23] and, second, an inflammatory phase mediated by macrophages [24] . Both have a common characteristic, hypoxemia, and this is why choosing the best respiratory support as soon as possible is of utmost importance for the clinical course of patients. Regrettably, sanitary activity during the COVID-19 pandemic is conditioned by what the WHO has defined as "multiple victim incidence", where more patients are generated than those who can be treated in optimal conditions [18] [20] . For this J o u r n a l P r e -p r o o f reason, many of the recent publications reference overwhelmed healthcare systems and compare the current situation to battlefield medicine practice. The first-choice treatment for ARDS is mechanical ventilation (MV) with the use of orotracheal intubation (OTI) [14] [15] [16] 21] . In the clinical event of resource and device shortage (full ICU, respirator shortage and lack of healthcare professionals), noninvasive respiratory support can be considered a valid alternative despite the worsening prognosis already published [11, 21, 25] . Both NIMV and CPAP or high-oxygen airflow therapy can be administered to patients by several devices depending on the availability and indication: oronasal masks, facial masks or helmets [26] [27] [28] . Through release valves, less nebulization is produced by helmets and the highest with oronasal masks. It is of high importance to take into account these devices in the COVID-19 pandemic context, as potential viral contamination to patients is caused by aerosolized particles, which is a limiting factor, as well as the limited availability of the CPAP/BiPAP device [29] [30] [31] . With the use of the Easybreath™ mask (ADM), we can address both issues. On the one hand, ADMs minimize contamination in the patient surroundings, as the facial silicone almost completely seals the faces of patient and because it is a semi-open device with just one output through the exhalatory port where air comes out already filtrated by a highly efficient N99,99 filter. This prevents exposure to other patients and healthcare professionals [29, 32, 33] . On the other hand, the technical requirements for ADMs are minimal: an oxygen flowmeter with as much oxygen airflow possible. All necessary pieces needed for the adaptation of ADMs have been designed by a multidisciplinary team of engineers and doctors (see Annex). 3D impression technology for medical use needs to work with nontoxic, inert materials that would prevent leaching of one or more substances contained in the adaptor that was originally of powder base. To avoid this and at the same time comply with regulatory rules EN 5356 and EN 13544, the preferred material is PA12 (SLS) [34, 35] . Our results show a rapid improvement in oxygen saturation maintained in time without any adverse events. In addition, adaptation of the ADM is safe for two main J o u r n a l P r e -p r o o f reasons. First, a 3D anti-suffocation valve adapted to our device allows for patients to inspire atmospheric air in case there is a pressure drop in the system (accidental decoupling of the oxygen source). Second, there was no hypercapnia or respiratory acidosis in any of the follow-up tests performed in patients, meaning that rebreathing did not take place. The mild hypercapnia that was detected in some patients may pertain to the highoxygen airflow administered (FiO2 administered close to 100%). This may also occur with common reservoir masks. Therapy should be suspended only if hypercapnia progressively increases or increases to moderate hypercapnia levels (pCO2> 50 mmHg) or if it is associated with acidosis of any degree (pH <7.35). In other words, patients should remove their masks if hypercapnia is present, despite being mild, if it increases in the first hours of use, if it is moderate or if any of the above factors are also associated with respiratory acidosis. Patients will be able to maintain masks with stable mild hypercapnia in the first 3 hours and if a lack of acidosis remains. One alveolar recruitment technique that helps patient oxygenation in ICUs for patients with ARDS is pronation [13] . Few studies have shown that the pronation maneuver in a non-ICU setting in patients treated with any type of respiratory support in the emergency room or who are hospitalized may improve the ventilatory/perfusion gradient of lungs and, therefore, hypoxemia [16] . Therefore, pronation, when necessary, is best tolerated by patients wearing masks. In our series, patients had low saturation levels even in pronation and used ADMs with up to >90% oxygen saturation in the supine position and with head elevated to 30 degrees. Some starting resources are necessary to be able to adapt to masks, but once the adaptation process is complete, masks can be completely reused by another patient, except for a high-efficiency filter following the Matachana sequence designed for our center: 1. Enzymatic detergent wash (Mediclean Forte™) 2. Rinse. 3. Wash the disinfector at 80° for 50 minutes to guarantee Ao=3000. This is the reference value used for thermoresistant germs, including hepatitis B or mycobacteria. 4. 85° drying turbine. This study has some limitations. The main limitation is derived from the design. We did not have a control group, as this was not possible in the critical clinical setting that has developed. Therefore, we cannot compare respiratory support with other therapies with the same characteristics, which would have been highly desirable. Additionally, 3D printing allows for the creation and testing of many prototypes in a rapid manner, but for midterm provisions and in a global pandemic setting, the final solution should be able to increase the production rate to respond to high demand when 3D printing is not available, perhaps via injection molding. Injection molding will make it possible to produce thousands of pieces per day at a lower cost, although initial investment (design and production of the mold) needs to be perfectly validated before starting the production process. Another disadvantage of 3D printing is that the production error has to be reduced to ±0,005 mm with a surface finish of 0,4 μm. This is not possible to guarantee with 3D printing methods, but it would be possible to produce with injection molding. We are aware of the limitations of the ADM proposal as an alternative to respiratory support, and assuming its use in pandemics and the deep shortage of certified alternatives, we can conclude that it complies with clinical requirements to be produced in other centers with limited resources [17] [18] [19] 36] , especially in developing countries. This is a therapy that provides an ADM device; it only requires oxygen connection with a flowmeter with a minimum airflow of 15 lpm. It has also shown a lack of significant adverse events, presenting an optimal initial tolerability in twentythree patients, and we propose it as a more comfortable interface option for those patients highly dependent on noninvasive respiratory support. J o u r n a l P r e -p r o o f J o u r n a l P r e -p r o o f Mild hypercapnia (%) 20 Skin irritation (%) 0 Eye irritation (%) 0 J o u r n a l P r e -p r o o f WHO declares COVID-19 a pandemic COVID-19: towards controlling of a pandemic Covid-19 and community mitigation strategies in a pandemic First case of 2019 novel coronavirus in the United States Estimation of COVID-19 outbreak size in Italy Outbreak investigation for COVID-19 in northern Vietnam COVID-19 and Italy: what next? Lancet. Lancet Publishing Group COVID-19 in Europe: the Italian lesson Novel 2019 coronavirus SARS-CoV-2 (COVID-19): an overview for emergency clinicians Clinical course and outcomes of critically ill patients with SARS-CoV-2 pneumonia in Wuhan, China: a single-centered, retrospective, observational study Xiaobo Yang* Hospitalized Patients with 2019 Novel Coronavirus-Infected Pneumonia in Wuhan, China Management of respiratory failure due to covid-19 Respiratory support for patients with COVID-19 infection Recommendations for Endotracheal Intubation of COVID-19 Patients Respiratory physiotherapy in patients with COVID-19 infection in acute setting: A Position Paper of the Italian Association of Respiratory Physiotherapists Clinical ethics recommendations for the allocation of intensive care treatments in exceptional, resource-limited circumstances: The Italian perspective during the COVID-19 epidemic The response of ilan's Emer ency edical System to the OVID-19 outbreak in Italy Hospital surge capacity in a tertiary emergency referral centre during the COVID-19 outbreak in Italy Emergency departments and the COVID-19 pandemic: Making the most of limited resources Clinical Consensus Recommendations Regarding Non-Invasive Respiratory Support in the Adult Patient with Acute Respiratory Failure Secondary to SARS-CoV-2 infection Structural basis of receptor recognition by SARS-CoV-2. Nature Receptor Recognition by the Novel Coronavirus from Wuhan: an Analysis Based on Decade-Long Structural Studies of SARS Coronavirus COVID-19: consider cytokine storm syndromes and immunosuppression High-flow nasal cannula may be no safer than noninvasive positive pressure ventilation for COVID-19 patients Helmet CPAP to Treat Acute Hypoxemic Respiratory Failure in Patients with COVID-19: A Management Strategy Proposal Treatment of acute hypoxemic nonhypercapnic respiratory insufficiency with continuous positive airway pressure delivered by a face mask: A randomized controlled trial High-flow nasal cannulae for respiratory support in adult intensive care patients Protecting health-care workers from subclinical coronavirus infection High-flow nasal cannula for COVID-19 patients: low risk of bio-aerosol dispersion More awareness is needed for severe acute respiratory syndrome coronavirus 2019 transmission through exhaled air during non-invasive respiratory support: Experience from China Staff safety during emergency airway management for COVID-19 in Hong Kong Activities of daily living after hip fracture: Profile and rate of recovery during 2 years of follow-up Three-dimensional (3D) printing of polymer-metal hybrid materials by fused deposition modeling. Materials (Basel) Enhancement of thermal, mechanical and physical properties of polyamide 12 composites via hybridization of ceramics for bone replacement How emergency departments prepare for virus disease outbreaks like COVID-19 Acknowledgement e ac no led e ristina rce for her re ision and translation of the manuscript and anuel ere -Espa a uniesa d, for their support in the early phases of COVID 19 pandemia. The authors want to acknowledge the effort and creativity in the design of the adapting parts of the mask to Juan Manuel Canalejo-Bautista (Airbus) and Alberto Molina Parga (CT Engineers)