key: cord-338900-8ojah695 authors: MacDonald, David S. MacDonald; Colosi, Dan C.; Mupparapu, Muralidhar; Kumar, Verdana; Shintaku, Werner H.; Mansur, Ahmad title: Guidelines for Oral and Maxillofacial Imaging: COVID-19 Considerations date: 2020-10-26 journal: Oral Surg Oral Med Oral Pathol Oral Radiol DOI: 10.1016/j.oooo.2020.10.017 sha: doc_id: 338900 cord_uid: 8ojah695 SARS-CoV-2, the virus causing the current COVID-19 pandemic, is not only highly infectious but can induce serious outcomes in vulnerable individuals including dental patients and dental health care providers (DHCP). Responses to COVID-19 have been published by the Centers for Disease Control and Prevention and the American Dental Association but a more specific response is required for the safe practice of oral and maxillofacial radiology. We aim to review the current knowledge of how the disease threatens patients and DHCPs and how to determine which patients are likely to be SARS-Cov-2 infected; consider how the use of personal protective equipment and infection control measures based on current best practices and science can reduce the risk of disease transmission during radiologic procedures; and examine how intraoral radiography, with its potentially greater risk of spreading the disease, might be replaced by extraoral radiographic techniques for certain diagnostic tasks. This is complemented by a flowchart that can be displayed in all dental offices. the Centers for Disease Control and Prevention and the American Dental Association but a more specific response is required for the safe practice of oral and maxillofacial radiology. We aim to review the current knowledge of how the disease threatens patients and DHCPs and how to determine which patients are likely to be SARS-Cov-2 infected; consider how the use of personal protective equipment and infection control measures based on current best practices and science can reduce the risk of disease transmission during radiologic procedures; and examine how intraoral radiography, with its potentially greater risk of spreading the disease, might be replaced by extraoral radiographic techniques for certain diagnostic tasks. This is complemented by a flowchart that can be displayed in all dental offices. Although aerosols and airborne contamination are created by commonly used dental equipment such as ultrasonic scalers, high-speed dental handpieces, air/water syringes, air polishing, and air abrasion, 1 techniques used in oral and maxillofacial radiology (OMR), particularly intraoral radiography, can also produce aerosols. The control or reduction of such aerosol generating procedures (AGP) is a principal strategy in the global response to the current COVID-19 (coronavirus disease 2019) pandemic. 1 As dental health care professionals (DHCP) return to practice following the prolonged lockdown provoked by this pandemic, they encounter an entirely changed world, requiring new systems of work. The American Dental Association (ADA) has fully adopted the Centers for Disease Control and Prevention (CDC) recommendations and applied them to almost every aspect of dental care in its ‗Return to Work Interim Guidance Toolkit', 2, 3 but the guidelines are still limited with regards to radiography. Although the first peer-reviewed report on this matter reflected the widespread confinement of radiography to extraoral projections, 4 due to the possible production of an aerosol by coughing and gagging during intraoral radiography, a letter to the editor advised the appropriate use of intraoral radiography when necessary .5 The death of a dental colleague in March due to COVID-19 reverberated throughout the dental world. The CDC COVID-19 response team reported that 37% of health-care workers who died were 65 years of age and over. 6 Furthermore, males, those with underlying health conditions, and those of minority ethnicities are particularly vulnerable to developing COVID-19 symptoms and, more importantly, developing a severe outcome that includes death (Table I) . 7, 8 In the absence of a vaccine, identification of our vulnerable colleagues is a priority. The purpose of this article is to 1) review the background of the COVID-19 pandemic and what is currently known about this disease, including signs and symptoms of infection and mechanisms of transmission; 2) list tactics with which DHCPs can minimize the risk of transmission of the disease between themselves and patients, with emphasis on preparing radiology equipment and accessories; and 3) consider how the prescription of radiographic techniques might be changed to provide the desired diagnostic information with minimal risk. The CDC defines DHCPs as -all paid and unpaid persons serving in dental healthcare settings who have the potential for direct or indirect exposure to patients or infectious materials, including: body substances, contaminated medical supplies, equipment, surfaces and air.‖ 1 COVID-19 is a highly infectious disease that is caused by the SARS novel coronavirus 2 (SARS Cov-2). 9 SARS CoV-2 spreads between -people who are in close contact with one another (within approximately 6 feet), through respiratory droplets produced when an infected person coughs, sneezes, or talks.‖ 9 This is due to the presence of the virus in an aerosol (an abbreviation of "aero-solution"), which is a suspension of fine solid particles or liquid droplets in air or another gas. 10 -The virus has been shown to persist in aerosols for hours, and on some surfaces for days under laboratory conditions.‖ 1 Death results not only from acute respiratory distress syndrome (ARDS), but also from organ failure. 11 The main signs and symptoms of COVID-19 are fever or chills, cough, shortness of breath or difficulty breathing, fatigue, muscle or body aches, headache, new loss of taste or smell, congestion or runny nose, nausea, vomiting, and diarrhea. 12 Identification of these manifestations in patients who are entering the clinic for radiographs permits the dentist to accomplish the first decision point in patient management: whether or not the patient has or is being investigated for this disease (Figure 1 ). It distinguishes between 2 separate groups of patients: those with or suspected of having COVID-19 and those who are not. This is the point where the dentist will decide to modify his/her radiographic activities (-Yes‖ in the decision tree) or proceed as normal (-No‖ in the decision tree). The early and prompt detection and isolation of patients diagnosed with or suspected of having COVID-19 is advised in order to minimize exposure of colleagues and other patients. 13 However, the CDC warns that -COVID-19 may be spread by people who do not show symptoms.‖ 12 Considering the nature and presentation of the disease, and the possibly serious outcomes for those infected with the virus, DHCPs should institute a clearly defined regimen to reduce the risk of transmission, as stated in Table II . The table is derived from the CDC's updated ‗Guidance for Dental Settings.' In the first instance a colleague developing the above signs and symptoms should not report for work or if developing them in the office should be sent home or to another destination specified by state or local health departments. Immediate emergency medical attention should be sought if a colleague or patient displays the following signs: trouble breathing, persistent pain or pressure in the chest, new confusion, inability to wake up or stay awake, and bluish lips or face. 12 As this list is not exhaustive, any other severe clinical manifestation should of course provoke similar urgency. 12 Each DHCP should be educated in how the SARS-CoV-2 virus can infect people and be trained in and have practiced the appropriate use of PPE prior to caring for patients. Further details included in recent CDC documentation 1, 14 have been summarized in Table II. To protect patients and co-workers, DHCPs should wear a facemask at all times while they are in a health care facility since this offers both source control and protection from exposure to splashes and sprays of infectious material from others.  DHCPs working in areas with minimal to no community transmission should continue to use eye protection or an N95 or higher-level respirator. Universal use of a facemask for source control is recommended for DHCPs. The DHCP in charge or the dental office owner should ensure that PPE of the appropriate quality (e.g., N95 or higher-level respirators, disposable-after-single-use isolation gowns) is available for the clinical team in the proper quantities. Face cloths are not PPE and should not be used in the care of COVID-19 (or suspected) patients. Other PPE includes protective eyewear. As the gaps between the glasses and the face do not protect the eyes from all splashes, sprays, and aerosols, face shields are required to guard against them. 14 A separate system of work will need to be created for radiographic procedures, which includes patient preparation, observing time-intervals between patients, and cleaning and decontamination after the patient has departed from the facility. In addition to ensuring that all DHCPs have the required PPE and are utilizing it properly, it is also important to consider the PPE requirements for patients who have or are suspected of having COVID-19 to manage the risk these patients pose to the dentist and clinical team members who receive all patients (emergency and non-emergency) in the dental office (Table II) . If emergency dental care is medically necessary for a patient who has or is suspected of having COVID-19, the DHCP should follow the CDC's interim document for healthcare settings. 14 In such a setting, patients should wear all recommended PPE including a facemask or cloth face covering to contain secretions and should be covered with a clean sheet. After arrival at their destination, the receiving radiology personnel and the transporter (if assisting with transfer) should perform hand hygiene and wear all recommended PPE. The potential for asymptomatic SARS-CoV-2 transmission underscores the importance of applying prevention practices to all patients, including social distancing, hand hygiene, surface decontamination, and having patients wear a cloth face covering or facemask while in a health care facility. DHCPs should limit clinical care to one patient at a time whenever possible. Set up operatories so that only the clean or sterile supplies and instruments needed for the dental procedure are readily accessible. Any supplies and equipment that are exposed but not used during the procedure should be considered contaminated and should be disposed of or reprocessed properly after completion of the procedure. A limited amount of evidence exists regarding the clinical effectiveness of ‗preprocedural mouth rinses' (PPMR) before intraoral radiography in order to reduce aerosol generation and thereby SARS CoV-2 viral transmission. There is some evidence, however, that while ethanol-based PPMRs (perhaps with essential oils) reduce the viral load, chlorhexidine does not. Povidone-iodine and hydrogen peroxide show some promise. 15 Nevertheless, it must be appreciated that -there is currently insufficient high-quality evidence to suggest that oral rinses are effective against SARS-CoV-2.‖ Therefore, oral rinses should not be used as alternatives to high quality PPE and rigorous infection control. 15 In light of COVID-19, the ADA has provided interim guidance for DHCPs, recommending the avoidance or reduction of intraoral radiography during the COVID-19 crisis. 16 As mentioned earlier, the virus can persist for long periods of time in aerosols. A potential source of aerosol production in intraoral radiography is gagging and coughing. In one study, the overall frequency of gagging during intraoral radiography was 13% but the frequency differed significantly between patients radiographed by trained radiographers (frequency of 9%) and by students (frequency of 26%). 17 Although gagging occurred when positioning intraoral receptors in all sites, the most common site was the maxillary molar area 17 . Recommendations of the ADA for radiographic prescription for common dental tasks (selection criteria) were first published in 1982; the most recent guidelines appeared in 2012 18 The broad thrust of these recommendations is still pertinent in the COVID-19 era; the prescription of every radiograph must arise from a particular clinical indication. 18 However, the constraints COVID-19 imposes upon dental practice might limit the hitherto free use of intraoral radiography, mainly due to the increased risk of producing a virus-laden aerosol. These problems prompt us to consider different technologies, such as dental panoramic radiographs (DPRs) and cone beam computed tomography (CBCT), to accomplish the goals of intraoral radiography, particularly in those cases where an aerosol is most likely to be generated by gagging or coughing (see Figure 1 ). The hitherto almost ‗routine' fullmouth survey (FMS) may have to become less ‗routine'. Indeed, oral and maxillofacial radiology (OMR) educators teach that the word ‗routine' has no place in the OMR vocabulary in accordance with the ADA selection criteria of 2012. 18 The flow chart in Figure 1 guides the prescription of radiographic procedures during the ‗recovery phase' of the COVID-19 pandemic. It is organized as a broad overview covering patients who are known or suspected to have COVID-19 and those who are not. Table III compares the strengths, limitations, and radiation burdens of intraoral and DPR and CBCT. Before to returning to Figure 1 it is important to reveal why intraoral radiography, the workhorse of radiography in dentistry, has been so compromised by COVID-19. As we have seen, intraoral radiography is potentially an AGP. Prior to a review of radiographic technologies, it is important to emphasize that these do not replace a thorough clinical examination and history taking. Although the most frequent reason for intraoral radiography, particularly bitewings, is the detection of caries, particularly proximal caries, it was revealed that -when diagnostic observations were translated into clinical management decisions using the rule that a noncavitated lesion should be treated nonoperatively and a cavitated lesion operatively, … visual-tactile method alone was the superior strategy, resulting in most correct clinical management decisions and most correct decisions regarding the choice of treatment.‖ 19 Due to the relative antiquity of most bitewingand-caries studies (now at least 3 decades old) and that CBCT can be accurate for displaying cavitation in proximal caries, Wenzel has suggested that new studies are required in both child and adult populations. Bitewing radiography remains the ‗state-of-the art' for the diagnosis of proximal caries. 20 The utilization of bitewings and periapical radiography in the current COVID-19 pandemic will now be discussed. Prior to the current COVID-19 emergency, an authority identified that such an infection would reveal the Achilles' heel of digital dental intraoral radiographic equipment; it cannot be sterilized. 21 The CDC's recent update on the pandemic for health care professionals 1 referred to their 2003 document. 22 Unfortunately this document was written just when digital radiography was entering mainstream dental practice and therefore was only able to offer limited advice. Since the most widely used system of sterilization in dentistry is autoclaving, which would destroy the sensors, barrier protection of the sensors or a return to analog film imaging are being considered. However, now that most dental offices in North America have converted to some form of digital radiography, the use of film is not a realistic option. With regards to photostimulable phosphor sensors (PSP; also called storage phosphor plates), the best practical solution is to decontaminate them between patients with 70% alcohol wipes (or other CDC-approved disinfectant solutions) and then insert these sensors into sealable plastic envelopes before their next use. These steps have been shown to provide adequate protection for storage phosphor plate systems. 23 Consideration of scanner contamination was not part of that report and should be taken into account in the current pandemic. The over half-century existence of DPR has seen it evolve in complexity of movement and from analog to digital technologies. Its principal advantages are delivery of a 2-dimensional panoramic display of the maxillomandibular complex in adequate detail with a comparatively low radiation dose. The DPR has traditionally been used to overview patients new to dental care, particularly those with disease obvious on clinical examination. After the completion of a thorough examination, its use as a supplemental investigation in a consecutive case series of over 6000 digital DPRs made on symptom-free new patients requesting only a dental exam or dental hygiene revealed at least one incidental finding that could require treatment in approximately one-third of the patients. 26 Although the majority of incidental findings were impacted teeth, 1% had areas of sclerosing osteitis associated with teeth that were likely nonvital and should be re-evaluated by clinical re-examination. 26 Furthermore, the patient-friendliness of the DPR has made it the first imaging modality for those patients with variable degrees of dental anxiety. In an investigation of dental anxiety among adult patients, only a DPR complementing the clinical examination revealed the source of dental pain, which was found to affect over three-quarters of patients with dental anxiety. 27 Further potential displacement of intraoral radiography by the DPR was suggested nearly 2 decades ago. Farman remarked that a reversal of the usual comparison of the DPR to bitewings as the gold standard to the assumption of DPR as the gold standard -might well turn out that the intraoral or bitewing series with its disadvantages of technical clumsiness, time consumption, additional dose, additional cost and infection control problems adds surprisingly little to the‖ DPR. 28 The last, infection control problems, precisely resonates with the current COVID-19 pandemic. Indeed, DPR is well-suited for patients diagnosed with or suspected to have COVID-19, because, with the exception of the bite block in dentate patients, there is nothing to enter the mouth that would provoke gagging or coughing and thus produce an aerosol. Although a DPR alone may not be adequate for the diagnosis of proximal caries for the entire dentition, it was shown in one investigation to be effective when used in combination with anterior periapical radiographs and bitewings, producing results similar to a full mouth series (FMS). 29 This alternative to the FMS avoids the disadvantages indicated above by Farman 28 by limiting gagging induced particularly by the maxillary molar area. 17 In addition, DPRs in one study displayed periapical lesions of the second and third maxillary molars better than periapical radiographs. 30 DPR has already not only substantially displaced intraoral radiography with regards to the pre-operative assessment of third molars; it can produce 3 radiographic signs that indicate a risk of postoperative sensory impairment. 31 Any subsequent preoperative CBCT may have little effect on the outcome of surgery. 32 The recommendations for the use of the DPR alone for periodontal bone loss have varied between studies, 33 and may reflect the DPR's magnification and slight rostrally-angled central ray. Generation of sectional images in DPR has been possible for nearly three decades as a component of some panoramic devices. Perhaps the most used and useful of these sectional views is the extraoral bitewing (EBW). EBW radiographs revealed significantly more caries and crestal bone loss in comparison to intraoral bitewings with high-to-excellent sensitivity in one investigation but produced more false-positives for these lesions, possibility in part due to reduced interproximal overlapping. 34 That study did not use Wenzel's ‗gold standard' for radiological diagnosis of caries by histological confirmation. 35 However, earlier studies that employed the gold standard provided conflicting evidence, with one paper reporting high specificity (and therefore few false-positives) for EBW 36 while another confirmed the increased likelihood of false positives for one of the units tested. 37 These findings reemphasize the need for careful clinical re-examination to confirm radiological findings. CBCT differs from medical computed tomography in that it produces images with better spatial resolution and lower radiation dose, occupying a smaller footprint in the operatory (similar to that of a DPR) and with fewer installation specifications (no floor strengthening or high-tension electricity supply required). 21 Nevertheless, the radiation dose is still greater than that of any conventional dental imaging technique and it varies between different manufacturers and models. 38, 39 CBCT is broadly divided into ‗dentoalveolar' CBCT, namely focused (small) and medium field-of-view (FOV) CBCT confined to the tooth bearing jaws, and ‗craniomaxillary' CBCT, using FOVs in excess of 8x8 cm. Larger FOVs generally impart more radiation to patients than smaller FOVs. 39 The advantage of the focused FOV is that it can be used with the highest spatial resolution (image detail) for that unit precisely for the area of clinical interest, thereby permitting a reduction in overall radiation dose. Although in pre-COVID-19 times, an intraoral radiograph could have sufficed, this now has to be balanced against the likelihood of inducing gagging or coughing in that patient. Nevertheless, a focused FOV CBCT may be indicated, particularly when evaluating a tooth for a periapical lesion, missed root canal, complex anatomy, or vertical root fracture. 40 Although CBCT was proved to be superior to conventional radiography by changing not only the diagnosis but also the treatment plans of such cases, it played a role in the assessment of root resorption and calcified root canals. 40 Although the diagnosis of caries has been mediated by conventional radiography, namely bitewings and periapicals, using CBCT to diagnose caries, particularly primary caries in a minimally restored mouth where image disruption by metal artifacts will be minimal, is an unprecedented concept for most dentists. Nevertheless, in view of the current COVID-19 pandemic and the fact that some high-quality work has already been published, albeit ex vivo, it should be considered during the current pandemic when obtaining intraoral radiographs is not a viable task. CBCT not only obviates the aforementioned false-positive problem of bitewings, 37 it is superior for caries detection, estimation of lesion depth, and detection of cavitation. 37 Two of the major downsides of using CBCT for primary caries diagnosis is the higher radiation dose, particularly in children, who are more vulnerable to the effects of radiation, and cost in comparison to conventional radiography. Another problem, for those children undergoing fixed-appliance orthodontics, is the effect of the appliance themselves. An ex vivo study reported that these devices prevented diagnosis of non-cavitated caries. 41 Although CBCT has also been used to assist in the diagnosis of secondary (recurrent) caries, its usefulness has been compromised by the artifacts produced by metal restorations. These artifacts are the spray (white lines) and beam-hardening (black bands) artifacts caused by the interaction of x-ray photons and metal restorations. CBCT performed better in the detection of recurrent caries when assessing composite restorations. 42 CBCT has already been used widely in the assessment of periodontal disease. An extensive systematic review by Haas et al. on the use of CBCT to assess periodontal bone defects reported that while CBCT could be useful for furcation-involved periodontal cases, it should only be used in cases where the information acquired by clinical and conventional radiographic evaluation is insufficient for treatment planning. 43 Although the spatial resolution of CBCT is inferior to intraoral radiography, its ease of use and patient-friendly attributes complement its superior volumetric display of the dental apparatus. Contrast resolution is still limited but CBCT -allows the distinction between tissues with minor differences and to display them with different gray density levels.‖ 44 Its early detection of crestal alveolar bone loss and display of the potentially complex patterns of bone loss, such as intrabony and cortical plate defects and molar furcation involvement, enhances the quality of diagnosis. 44 Small FOV CBCT with a high-spatial resolution can be employed in selected cases -to aid in decision making of when and how to treat a specific tooth or teeth.‖ . 45 A systematic review -showed a high accuracy of CBCT in visualizing periodontal structures and demonstrated the usefulness of CBCT in regenerative periodontal surgery of maxillary molars.‖ . 46 CBCT appears to be an accurate method to describe vertical periodontal bone loss as it agreed better with the clinical measurements with fewer deviations than periapical radiographs. 46 Anomalies, such as impacted teeth, that affect the anatomically complex maxillary sinus are optimally investigated by cross-sectional imaging. Furthermore, CBCT was invaluable in the discernment of the more complicated root pattern of maxillary molars not only for endodontic purposes, 40 but also presurgical planning that contemplates extraction. 48 Observation of severe external root resorption of the maxillary second molar by the impacted third molar often resulted in the removal of the former and retention of the latter. 47 CBCT of impacted maxillary canines should be evaluated both by multiplanar reconstruction (MPR) and by -curved‖ reconstructions and not just by one. 48 CBCT has now been extensively applied to a wide range of lesions arising within or affecting the jaw bones. 21, 49,50 CBCT imparts a larger radiation dose to the patient than conventional radiography, including panoramic radiographs. This larger dose has been displayed for a wide range of manufacturers of CBCT devices. This is of particular importance to the child patient. Horner et al. advised that -CBCT should only be used when adequate conventional radiographic examination has not answered the questions for which imaging was required.‖ 51 The CDC recommends that the -DHCP should ensure that environmental cleaning and disinfection procedures are followed consistently and correctly after each patient (however, it is not necessary that DHCP should attempt to sterilize a dental operatory between patients).‖ 1 The CDC 1 further recommends that this be done in accordance to the CDC's 2003 guidelines. 22 To clean and disinfect the radiology operatory after a patient without suspected or confirmed COVID-19, it is recommended to wait 15 minutes after completion of clinical care and the exit of each patient to begin cleaning and disinfecting room surfaces to allow for droplets to fall from the air. Therefore, DHCPs should delay entry into the operatory until a sufficient time has elapsed for enough air changes to remove potentially infectious particles. 13, 52 Air changes per hour' is the ratio of the volume of air flowing through a space in a certain period of time (the airflow rate) to the volume of that space (the room volume). Though ideally this should be 12 air changes per hour, particularly in new construction or recent renovations, a minimum of 6 is acceptable. Patients should be scheduled at intervals 20 to 30 minutes apart to allow for this and for disinfection of the room. 14 In addition to ensuring sufficient time for enough air changes to remove potentially infectious particles, DHCPs should clean and disinfect environmental surfaces and equipment before the room is used for another patient. DHCPs must perform a standard antiseptic wipe down of equipment, including lead/leadequivalent aprons, using quaternary ammonium/alcohol impregnated wipes or other Environmental Protection Agency (EPA)-approved disinfectants as listed in Table IV . 53 Ensure that the lead/lead-equivalent apron and the thyroid collar are stored correctly. The apron should not be folded as this not only cracks the lead/lead-equivalent material, which reduces its radiation protection, but also may crack the surface which makes it more difficult to disinfect. Preventive steps to curtail aerosols, such as the use of specially designed high efficiency particulate arrestor filters equipped with ultraviolet (UV) light, have also been advocated. pandemic these modalities should be revisited for use in a dental context. This paper offers a strategy for the practice of oral and maxillofacial radiology during the COVID-19 pandemic. Although some of the evidence has been derived ex vivo rather than clinically, particularly with regards to caries and also CBCT use, these serve as pointers to their possible application in the appropriate clinical situation. As the current COVID-19 pandemic continues to unfold, so will the need to develop and reconfigure our current technologies. This could have the effect of, at least, inspiring the manufacturers of devices used in radiology, particularly those of CBCT, to design and develop their products to meet additional needs, particularly by continuing to drive down radiation dose. However, the CDC advises that we -(s)tay informed. Consult regularly with your state or local health department for region-specific information and recommendations. Monitor trends in local case counts and deaths, especially for populations at higher risk for severe illness.‖ 56 pandemic with respect to oral and maxillofacial radiology. Telephone-triage to determine whether patients need to be seen in a dental setting Advise patients to minimize the number of accompanied visitors and inform them that all must wear face masks/covering and will be subject to screening for fever and symptoms Physical (in-person) screening and triage of patients at entry into the dental office. Ensure everyone complies with respiratory hygiene (wear face masks/coverings) and applied cough etiquette and hand hygiene (ABHR) Take temperature (fever is equal to or greater than 100 o F) Inquire as to whether the patient has already been asked to self-quarantine Install physical barriers at reception areas Direct COVID-19-confirmed or suspected patients to the operatory for their emergency treatment and NOT to the waiting room Avoid or minimize aerosol generating procedures (AGP) AGPs are commonly created in dentistry by ultrasonic scalers and high-speed dental hand pieces, air/water syringes, and air polishing and abrasion, but also by patients when gagging and/or resisting intra-oral radiography, and by children. Figure 1 and Table III Airborne infection isolation rooms Single-patient rooms at negative pressure relative to surrounding areas with a minimum of 6 air changes /hour*. The operatory door should be closed except upon entry. Exhaust air directly to the outside or filtered through a HEPA filter. HEPA positioning Should be close to the patient's head, but NOT such that any DHCP gets between it and the patient. This is relevant when the DHCP is placing intraoral sensors in the mouth After the patient has left -DHCP should ensure that environmental cleaning and disinfection procedures are followed consistently and correctly after each patient.‖ 1 Use the appropriate EPA-standard cleaning materials. See Table IV ABHR, alcohol-based hand rub; DHCP, dental health care professional; EPA, Environmental Protection Agency; HEPA, high efficiency particulate air; PPE, Personal protective equipment *Air changes per hour: the ratio of the volume of air flowing through a space in a certain period of time (the airflow rate) to the volume of that space (the room volume). This ratio is expressed as the number of air changes per hour. Guidance for dental settings Dental practitioners' role in the assessment and containment of coronavirus disease (COVID-19): Evolving recommendations from the centers for disease control American Dental Association. Return to Work Toolkit Coronavirus disease 2019 (COVID-19): Emerging and future challenges for dental and oral medicine Letter to the Editor: Use of Dental Radiography in the COVID-19 Pandemic Characteristics of health care personnel With COVID-19 -United States COVID-19 and the cardiovascular system: implications for risk assessment, diagnosis, and treatment options Development of an Objective Risk Stratification Tool to facilitate workplace assessments of healthcare workers when dealing with the CoViD-19 pandemic World Health Organisation (WHO) Ten things we learned about COVID-19 Centers for Disease Control and Prevention (CDC). Symptoms of COVID-19 Radiology department preparedness for COVID-19: radiology scientific expert panel Interim Infection Prevention and Control Recommendations for Healthcare Personnel During the Coronavirus Disease Can oral rinses play a role in preventing transmission of Covid 19 infection? Evid Based Dent Gagging in dental radiography Dental radiographic examinations: Recommendations for patient selection and limiting radiation dose. Revised 2012. U.S. Department of Health and Human Resources. Food and Drug Administration Wenzel A. Radiographic display of carious lesions and cavitation in approximal surfaces: Advantages and drawbacks of conventional and advanced modalities Oral and maxillofacial radiology: a diagnostic approach‖ Guidelines for infection control in dental healthcare settings Infection control in digital intraoral radiography: evaluation of microbiological contamination of photostimulable phosphor plates in barrier envelopes Perforation rate of intraoral barriers for direct digital radiography Radiographic endodontic working length estimation: comparison of three digital image receptors. Oral Surg Oral Med Oral Pathol Oral Radiol Endod Incidental findings in a consecutive series of digital panoramic radiographs Dental anxiety, concomitant factors and change in prevalence over 50 years There are good reasons for selecting panoramic radiography to replace the intraoral full-mouth series. Oral Surg Oral Med Oral Pathol Oral Radiol Endod Comparing the accuracy of panoramic and intraoral radiography in the diagnosis of proximal caries Radiological assessment of periapical status using the periapical index: comparison of periapical radiography and digital panoramic radiography Use of panoramic radiography to predict postsurgical sensory impairment following extraction of impacted mandibular third molars Does 3-dimensional imaging of the third molar reduce the risk of experiencing inferior alveolar nerve injury owing to extraction?: A meta-analysis The emerging role of maxillofacial radiology in the diagnosis and management of patients with complex periodontitis Accuracy of extraoral bite-wing radiography in detecting proximal caries and crestal bone loss The choice of gold standard for evaluating tests for caries diagnosis Intraoral versus extraoral bitewing radiography in detection of enamel proximal caries: an ex vivo study Ex vivo evaluation of new 2D and 3D dental radiographic technology for detecting caries Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation Effective dose of dental CBCT -a meta analysis of published data and additional data for 9 CBCT units Clinical decision making and importance of AAOMR/AAE position statement for CBCT examination in endodontic cases Validity of micro-CT for in vitro caries detection: a systematic review and metaanalysis The effects of orthodontic materials on the accuracy of periapical radiography-based caries detection Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT Precision of cone beam CT to assess periodontal bone defects: a systematic review and meta-analysis Periodontal disease Accuracy and usefulness of CBCT in periodontology: A systematic review of the literature Ex vivo comparison of CBCT and digital periapical radiographs for the quantitative assessment of periodontal defects Impact of CBCT on treatment decision related to surgical removal of impacted maxillary third molars: does CBCT change the surgical approach? Cone-beam computed tomography (CBCT) in the UBC Graduate Orthodontic Program International/American/Canadian Association of Dental Research. Vancouver Cone beam computed tomography and maxillofacial diagnosis.‖. In: -Maxillofacial cone beam computed tomography‖ Eds Malignant lesions in the anterior maxilla Diagnostic efficacy of cone beam computed tomography in paediatric dentistry: a systematic review COVID-19 Task Force* RSNA COVID-19 Task force: best practices for radiology departments during COVID-19. RNSA Environmental Protection Agency. List N: Disinfectants for use against SARS-CoV-2 Efficacy of an automated multiple emitter wholeroom ultraviolet-C disinfection system against coronaviruses MHV and MERSCoV Miscellaneous inactivating agents: Guideline for disinfection and sterilization in healthcare facilities Framework for healthcare systems providing Non-COVID-19 clinical care during the COVID-19 pandemic