id author title date pages extension mime words sentences flesch summary cache txt cord-281663-c2okrt2b Sella, Nicolò Positive end-expiratory pressure titration in COVID-19 acute respiratory failure: electrical impedance tomography vs. PEEP/FiO(2) tables 2020-09-01 .txt text/plain 708 59 52 title: Positive end-expiratory pressure titration in COVID-19 acute respiratory failure: electrical impedance tomography vs. Electrical impedance tomography (EIT) offers this opportunity by bedside estimating both alveolar collapse and lung overdistension throughout a decremental PEEP trial [5] . This investigation (Ethics Committee approval: Ref: 4853/AO/20-AOP2012) aims to assess the agreement between EIT-based PEEP values and those recommended by the higher and lower PEEP/FiO 2 tables [6] in a series of consecutive intubated COVID-19 hARF patients, admitted to intensive care unit at our institution. In conclusion, we confirm the rationale for individualized PEEP setting in COVID-19 patients intubated for Fig. 1 Bland-Altman plot, evaluating the agreement between PEEP EIT and the PEEP values proposed by the higher (a) and lower (b) PEEP/FiO 2 tables from the ALVEOLI trial [6] . Electrical impedance tomography for positive end-expiratory pressure titration in COVID-19-related acute respiratory distress syndrome Higher versus lower positive endexpiratory pressures in patients with the acute respiratory distress syndrome ./cache/cord-281663-c2okrt2b.txt ./txt/cord-281663-c2okrt2b.txt