[PDF] Quantitative conjunctival provocation test for controlled clinical trials. | Semantic Scholar Skip to search formSkip to main content> Semantic Scholar's Logo Search Sign InCreate Free Account You are currently offline. Some features of the site may not work correctly. DOI:10.3414/ME13-12-0142 Corpus ID: 24859675Quantitative conjunctival provocation test for controlled clinical trials. @article{Srndi2014QuantitativeCP, title={Quantitative conjunctival provocation test for controlled clinical trials.}, author={I. S{\'a}r{\'a}ndi and D. P. Cla{\ss}en and A. Astvatsatourov and O. Pfaar and L. Klimek and R. M{\"o}sges and T. M. Deserno}, journal={Methods of information in medicine}, year={2014}, volume={53 4}, pages={ 238-44 } } I. Sárándi, D. P. Claßen, +4 authors T. M. Deserno Published 2014 Medicine Methods of information in medicine BACKGROUND The conjunctival provocation test (CPT) is a diagnostic procedure for the assessment of allergic diseases. Photographs are taken before and after provocation increasing the redness of the conjunctiva due to hyperemia. OBJECTIVE We propose and evaluate an automatic image processing pipeline for objective and quantitative CPT. METHOD After scale normalization based on intrinsic image features, the conjunctiva region of interest (ROI) is segmented combining thresholding, edge… Expand View on PubMed isarandi.github.io Save to Library Create Alert Cite Launch Research Feed Share This Paper 7 CitationsBackground Citations 3 Methods Citations 2 View All Figures, Tables, and Topics from this paper figure 1 table 1 figure 2 figure 3 figure 4 figure 5 figure 6 figure 7 figure 8 figure 9 figure 10 View All 11 Figures & Tables Erythema Region of interest:Presence or Identity:Point in time:*:Nominal Hyperemia algorithm photograph 7 Citations Citation Type Citation Type All Types Cites Results Cites Methods Cites Background Has PDF Publication Type Author More Filters More Filters Filters Sort by Relevance Sort by Most Influenced Papers Sort by Citation Count Sort by Recency Digitally Analyzed Conjunctival Redness: Does Repeated Conjunctival Provocation Intrinsically Cause Local Desensitization of the Eye? Claas Gloistein, A. Astvatsatourov, S. Allekotte, R. Mösges Medicine International Archives of Allergy and Immunology 2015 6 Save Alert Research Feed Reliability of a New Symptom Score in a Titrated Quantitative Conjunctival Provocation Test Supported by an Objective Photodocumentation O. Pfaar, D. P. Claßen, A. Astvatsatourov, L. Klimek, R. Mösges Medicine International Archives of Allergy and Immunology 2018 4 Save Alert Research Feed Validation of Computerized Quantification of Ocular Redness E. Sirazitdinova, Marlies Gijs, Christian J F Bertens, T. Berendschot, R. Nuijts, T. M. Deserno Computer Science, Medicine Translational vision science & technology 2019 3 PDF View 10 excerpts, cites methods and background Save Alert Research Feed Liposomal Eye Spray Is as Effective as Antihistamine Eye Drops in Patients with Allergic Rhinoconjunctivitis Induced by Conjunctival Provocation Testing Anne-Nele Grzella, S. Schleicher, +4 authors R. Mösges Medicine International Archives of Allergy and Immunology 2019 2 Save Alert Research Feed Conjunctival allergen provocation test : guidelines for daily practice J-L Fauquert, M. Jędrzejczak-Czechowicz, +11 authors A. Leonardi Medicine Allergy 2017 40 PDF Save Alert Research Feed Multimodal Data Acquisition at SARS-CoV-2 Drive Through Screening Centers: Setup Description and Experiences in Saarland, Germany P. Flotho, M. Bhamborae, +4 authors D. Strauss Computer Science, Medicine medRxiv 2020 PDF View 2 excerpts, cites background and methods Save Alert Research Feed Medical informatics, biometry and epidemiology. Recent developments and advances. H. Handels, J. Ingenerf Medicine Methods of information in medicine 2014 View 1 excerpt, cites background Save Alert Research Feed References SHOWING 1-10 OF 23 REFERENCES SORT BYRelevance Most Influenced Papers Recency Automatic conjunctival provocation test combining Hough circle transform and self-calibrated color measurements S. Bista, I. Sárándi, S. Dogan, A. Astvatsatourov, R. Mösges, T. M. Deserno Mathematics, Engineering Medical Imaging 2013 5 PDF Save Alert Research Feed Objectifying the Conjunctival Provocation Test: Photography-Based Rating and Digital Analysis S. Dogan, A. Astvatsatourov, +4 authors R. Mösges Biology, Medicine International Archives of Allergy and Immunology 2013 18 View 3 excerpts, references background and methods Save Alert Research Feed Quantification of conjunctival vascular reaction by digital imaging. F. Horak, U. Berger, R. Menapace, N. Schuster Medicine The Journal of allergy and clinical immunology 1996 33 Save Alert Research Feed Image Analyses of the Kinetic Changes of Conjunctival Hyperemia in Histamine-Induced Conjunctivitis in Guinea Pigs A. Fukushima, T. Tomita Medicine Cornea 2009 17 Save Alert Research Feed Automated measurement of bulbar redness. P. Fieguth, T. Simpson Medicine Investigative ophthalmology & visual science 2002 70 PDF View 1 excerpt, references background Save Alert Research Feed Automated hyperemia analysis software: reliability and reproducibility in healthy subjects Tsuyoshi Yoneda, T. Sumi, A. Takahashi, Y. Hoshikawa, M. Kobayashi, A. Fukushima Medicine Japanese Journal of Ophthalmology 2011 26 Save Alert Research Feed Comparison of Conjunctival and Nasal Provocation Test in Allergic Rhinitis to House Dust Mite H. Riechelmann, Barbara Epple, Gunther Gropper Medicine International Archives of Allergy and Immunology 2003 60 View 1 excerpt, references background Save Alert Research Feed A comparison of manual and automated methods of measuring conjunctival vessel widths from photographic and digital images C. Owen, T. Ellis, E. Woodward Mathematics, Medicine Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians 2004 14 Save Alert Research Feed Automatic strabometry by Hough-transformation and covariance-filtering T. M. Deserno, A. Kaupp, R. Effert, D. Meyer-Ebrecht Computer Science Proceedings of 1st International Conference on Image Processing 1994 3 Save Alert Research Feed OC ToGo: bed site image integration into OpenClinica with mobile devices D. Haak, J. Gehlen, S. Jonas, T. M. Deserno Computer Science, Engineering Medical Imaging 2014 6 Save Alert Research Feed ... 1 2 3 ... Related Papers Abstract Figures, Tables, and Topics 7 Citations 23 References Related Papers Stay Connected With Semantic Scholar Sign Up About Semantic Scholar Semantic Scholar is a free, AI-powered research tool for scientific literature, based at the Allen Institute for AI. Learn More → Resources DatasetsSupp.aiAPIOpen Corpus Organization About UsResearchPublishing PartnersData Partners   FAQContact Proudly built by AI2 with the help of our Collaborators Terms of Service•Privacy Policy The Allen Institute for AI By clicking accept or continuing to use the site, you agree to the terms outlined in our Privacy Policy, Terms of Service, and Dataset License ACCEPT & CONTINUE